Страница 2: ...notice For more information please consult with a Baicells technical engineer or the support team Refer to the Contact Us section below Disposal of Electronic and Electrical Waste Pursuant to the WEEE...

Страница 3: ...This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with...

Страница 4: ...tall GPS Antenna 15 3 3 Install eNB on Pole or Wall 16 3 3 1 Install on Pole 16 3 3 2 Install on Wall 18 3 4 Connect Cables 20 3 4 1 Cable Laying Requirements 20 3 4 2 Connect GPS Antenna Cable 21 3 4...

Страница 5: ...ure 2 2 LEDs and Interfaces 11 Figure 2 3 Weatherproofing 13 Figure 2 4 Weatherproofing GPS Antenna 14 Figure 2 5 CloudCore Login Page 14 Figure 3 1 Installation Process Overview 15 Figure 3 2 GPS Ins...

Страница 6: ...3 22 Management Server 33 Figure 3 23 Quick Setting 35 Figure 3 24 Carrier Setting 36 Figure 3 25 Reboot 36 Figure 3 26 Cell Status eNB GUI 37 Figure 3 27 Cell Status OMC 37 Figure 3 28 OMC eNB Monito...

Страница 7: ...s a 2x1W single carrier eNB two 2x1Ws single carrier eNBs Dual Carrier Split Sector or a 4x1W Carrier Aggregation CA eNB The Nova436Q supports broadband data access providing various data service tran...

Страница 8: ...one of several modes Single Carrier SC Carrier Aggregation CA mode based on software license Dual Carrier DC split mode based on software license HaloB mode embedded in the base software Citizens Bro...

Страница 9: ...andwidth per carrier Provides excellent Non Line of Sight NLOS coverage Peak rate is a configurable parameter using special Subframe Assignment SA o 2x20 MHz per carrier SA1 DL 80 Mbps UL 28 Mbps SA2...

Страница 10: ...he tools shown in Table 2 2 Figure 2 1 Packout Table 2 1 Materials Item Description Power cable 16 AWG e g 14 AWG shorter than 330 feet 100 meters Power plug The plug that connects the power cable to...

Страница 11: ...rill and drill heads Hammer Phillips head screwdriver Cable vice crimper Tape measure 0 05 cm 5 mm L shape Allen wrench T7 screwdriver head 2 2 LEDs and Interfaces Figure 2 2 Table 2 3 and Table 2 4 e...

Страница 12: ...36Q can be installed on a pole or a wall For the best signal coverage place the eNB in an unobstructed location In addition to network planning when determining where to place the eNB you need to cons...

Страница 13: ...using one ground screw The connection of the grounding points and ground bar needs to be tight and reliable Rustproofing the terminals e g with antioxidant coating or grease is required 2 5 Weatherpro...

Страница 14: ...plications Operations Management Console OMC to manage network elements and Business and Operation Support System BOSS to manage subscribers If you have not already set up a Baicells CloudCore account...

Страница 15: ...No major blocking from buildings in the vicinity Make sure the space atop is at least 45 degrees unblocked by any buildings The GPS antenna should be installed within 45 degrees to the lightning rod...

Страница 16: ...GPS Installation Requirements The GPS antenna system is assembled in manufacturing before packing The only installation step is to fix the GPS mounting bracket on the eNB with the M4 14 screws Figure...

Страница 17: ...four hex nuts of the assembled pole bracket Slide the two omega clamps to the left and then turn them up or down Figure 3 4 Figure 3 4 Omega Clamps 2 Attach the bracket to the pole considering the hei...

Страница 18: ...ounting bracket Figure 3 6 Figure 3 6 Attach eNB to Bracket 4 Tighten the bolt on the top of the bracket using a Phillips head screwdriver to complete the installation Figure 3 7 Figure 3 7 Completed...

Страница 19: ...n in Figure 3 8 Mark the drilling locations using a pencil or marker 3 Drill two holes in the wall to match the size of the wall bracket holes Figure 3 8 Mark and Drill Holes 4 Check the up down direc...

Страница 20: ...ordinary 5 in 127 mm Bending radius of power cable and grounding cable triple the diameter of the cable The minimum bend radius of the optical fiber is 20 times the diameter of the optical fiber Bind...

Страница 21: ...k tube to the top joint and pull out the strip 5 Connect the other end of the RF cables to the external antennas which also need weatherproof protection 3 4 4 Connect Optical Fiber 1 Unscrew the three...

Страница 22: ...g cavity 5 The power cable lays along the slot and stretches out of the wiring cavity 6 The input of the power adaptor connects to the outlet If the outlet is indoors place the power adaptor indoors I...

Страница 23: ...at the outdoor location the other end of the ground cable needs to connect to a good earth grounding point Figure 3 13 Figure 3 13 Connecting Cables and Grounding Screws Before installing the eNB at...

Страница 24: ...ses you have purchased and or in HaloB mode which is embedded in the base software The Nova436Q also supports CBRS SAS operation When first installing and testing the Nova436Q Baicells recommends conf...

Страница 25: ...a static IP address within the MGMT subnet The default IP address for the MGMT interface is http 192 168 150 1 24 Step 2 Open a Web browser and enter the following IP address http 192 168 150 1 Step 3...

Страница 26: ...mware Follow the steps below to ensure you are using the most recent software version before configuring the eNB 3 6 2 1 Upgrade Firmware from eNB GUI 1 Download the most recent firmware file from Bai...

Страница 27: ...nt to upgrade 6 Next to File List select deselect Retain Configuration Under Select choose the software version by clicking in the empty cell a blue checkmark will appear 7 Choose the Execute Type whi...

Страница 28: ...LTE NMS The WAN LAN VLAN fields are described in Table 3 1 If the IP Access Mode field is set to DHCP and the LGW function is ON section 0 the Connect Type field must be modified The IP address of the...

Страница 29: ...to enable the interface Four IP addresses are the maximum number the eNB supports IP Access Mode Used to select the desired interface protocol DHCP Static IP IPv6 DHCP or IPv6 Static IP Current IP Th...

Страница 30: ...imized route from the routing table Figure 3 20 Bridge Transfer in the data link layer LGW Interface Binding The IP address connects to the LGW Select from configured interfaces Default is WAN interfa...

Страница 31: ...ding IP If LGW Mode Router and Static Address ON Figure 3 20 enter the IP address to bind to the IMSI You can add more than one IP address Figure 3 20 LGW Router 3 6 4 3 Static Routing When using stat...

Страница 32: ...eway IP address 3 6 5 Configure the Management Server In the BTS Setting Management Server window you will enter the network management service NMS information Figure 3 22 When using the Baicells Clou...

Страница 33: ...icells CloudCore are provided a unique CloudKey identifier that can be used when configuring CPEs and eNBs If entered in this field when the device is powered on it will immediately associate to the o...

Страница 34: ...0 5 0 9 Do not change these settings except when connecting to a Local private network EPC or different vendor s Evolved Packet Core EPC Second you must enter the operator s planned settings for Band...

Страница 35: ...using Dual Carrier DC split mode depending on which licenses you have purchased Single carrier no CA means only Cell 1 will operate and use only two RF ports instead of four Operators may need to use...

Страница 36: ...e the basic configuration settings are saved reboot the eNB There are two options for rebooting in the eNB GUI From the landing page of the eNB GUI navigate to System Reboot or select Reboot under the...

Страница 37: ...ic Info and check the Cell Status field Figure 3 26 It should show Active Also check that GPS Sync Status is reported as Synchronized OMC Go to eNB Monitor to see if the Cell Status shows Active and t...

Страница 38: ...Setting Before commercial operation Baicells recommends implementing cell site acceptance testing of a new site to ensure the service meets expectations to document network speeds at various locations...

Страница 39: ...communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING...