BAFFCO BMS 210AD Скачать руководство пользователя страница 1

 

 

     

 

Us

er 

Man

ual

 

V.

 1.

1

 

2014

 

 

Weld Anal

yzer 

– 

B

MS

 2

1

0A

D

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAFFCO 

Flat 10, No. 6, Ezatipour Street, 
Sattari cross Hakim highways,  
1471836837, Tehran, Iran  

Telephone: (+9821) 44004100, 44004200   

Telefax: (+9821) 44004300 

BAFFCO 

Flat 10, No. 6, Ezatipour Street, 

Содержание BMS 210AD

Страница 1: ...User Manual V 1 1 2014 Weld Analyzer BMS 210AD BAFFCO Flat 10 No 6 Ezatipour Street Sattari cross Hakim highways 1471836837 Tehran Iran Telephone 9821 44004100 44004200 Telefax 9821 44004300 BAFFCO...

Страница 2: ...ick Start with BMS210AD 14 7 Operation and Setting the Instrument 15 7 1 Measuring AC Continuous Current 15 7 2 Measuring AC Pulse Welding Current 16 7 3 Measuring Rectified Current DC 18 7 4 Measurin...

Страница 3: ...C or less than 0 C Location with humidity over 90 Location where there is a radio frequency noise source Location where chemical substances exist Location where expected frequently condensation occurs...

Страница 4: ...lyzer BMS 210AD www BAFFCO com Edition July 2014 2 Packaging List BMS210AD Instrument Toroid 9V 1A Adaptor BMS Utility Installer CD USB Cable Force Probe Optional Instrument Caring Bag BMS210AD User M...

Страница 5: ...of 15 Current Pulsations as One Measuring Maximum Current Pulse Duration 99 Cycle Auto Save and Monitoring Details of each Current Pulse Including I_RMS I_MAX Conduction Angle Cool Time between Two C...

Страница 6: ...s DC B AC Continuous Current Measurement Real Time Monitoring of Real RMS Current Three Ranges of Current Measuring 0 5kA to 5kA 5kA to 20kA 20kA to 100kA C Rectified Current DC Measurement Real Time...

Страница 7: ...History Page to Show Archived Records Setting Page to Set Bellow Parameters Ignoring Undesired First Time Ignoring Undesired Last Time Setting Maximum Acceptable Cool Time between Two Pulses Current...

Страница 8: ...ng of Average of Force up to 2000 kgf F PC Software Utility Archiving All Measured Current and Force Records in PC with Their Details Graph Results of Measured Values PrintResults of Measured Values w...

Страница 9: ...July 2014 Auto Sensor Current Force Detection Fully User Friendly Operation USB Port Light and Compact Casing Accessories Toroidal Current Sensor Force Sensor Optional Adaptor Rigid Bag for Carrying S...

Страница 10: ...Weld Analyzer BMS 210AD www BAFFCO com Edition July 2014 4 Dimensions 10 10...

Страница 11: ...eration To Turn instrument on press and hold Power key for a second To turn instrument off press Power key again device will ask you about turning off the system select YES to response the system then...

Страница 12: ...hree minutes back light of screen will be turned off and this situation will remain for seven minutes The instrument will make a beep sound to inform user that the system will be turned off in a few s...

Страница 13: ...r B Force Measuring Step1 Turn the instrument on by pressing the power button Step2 Connect force sensor connector to the instrument s input terminal Step3 Press Setting button in order to move to for...

Страница 14: ...ved 7 1 Measuring AC Continuous Current Like any clamp current meter you can use the instrument to measure current BMS210AD applies the mathematical calculation to find current value By using this met...

Страница 15: ...ts for a very short time and may have several train pulses like the resistance welding current put the instrument in this mode There are some selections to match the device with current behavior more...

Страница 16: ...ween them they are recognized as one measuring and save in the same record Set AC first cycle This parameter value means the device ignores some cycles of current according amount of first cycle For e...

Страница 17: ...DC If the current is rectified and average is not zero you can measure the current by putting the instrument in DC current mode In this case current can be a DC or medium frequency welding current The...

Страница 18: ...ce ignores some starting time of the current according amount of rise time the parameter unit is 10mSec for example if you set this parameter to 100 1 Second at the begging of the current will not be...

Страница 19: ...by applying appropriate sensor Toroid Load Cell To measure Electrode force fallow bellow steps 1 At the first time it is necessary to put the force transducer lode cell in the fully no lode situation...

Страница 20: ...undesired impact to the sensor at the beginning of measuring Last Time means at what exact time instrument will finish measuring force This is useful if you want to ignore some undesired impact to the...

Страница 21: ...D www BAFFCO com Edition July 2014 7 5 Measuring Continuous Force In setting page choose force continuous mode In Continuous force mode there is only force trigger parameter Set the value and go back...

Страница 22: ...l 108 Current Channel2 offset fail 109 Current Channel3 offset fail 110 Current Channel4 offset fail 111 AC Current range1 calibration factor is invalid memory error 112 AC Current range2 calibration...

Страница 23: ...s follow below steps 1 Press History key 2 By auto mode detection feature the history of measuring force or current will be illustrated 3 By using Arrow keys record number can be selected As described...

Страница 24: ...after this time the instrument will be powered off 10 2 Replacing the internal battery BMS210AD equipped by a rechargeable battery After a long time the battery storage ability may reduce In this cas...

Страница 25: ...interconnects with BMS Utility Ver 1 1 By this interconnection it is possible to transfer measuring data to a PC and archive graph and see more details on the monitor to clear internal memory and seve...

Страница 26: ...tion is required to keep it at acceptable accuracy level For calibration it is necessary to send the BMS210AD with its measuring accessories toroid and or force sensor to the company It is recommended...