Electronic Preset Meter

Model EPM2-STD, Standard Series

AUT-UM-00933-EN-06 (April 2019)

User Manual

Содержание Oval Gear EPM2-STD

Страница 1: ...Electronic Preset Meter Model EPM2 STD Standard Series AUT UM 00933 EN 06 April 2019 User Manual...

Страница 2: ...6 Auto Batch Mode 7 Operating Mode Functions 7 Re settable and Accumulated Totals 7 Emergency Override 7 Error Codes 7 Service 8 Low Battery 8 Changing the Batteries 8 Change Factory Settings 8 Verify...

Страница 3: ...purpose Do not modify or alter the equipment Do not leave equipment unattended while dispensing Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum work...

Страница 4: ...Accumulated Total and Scale Factor 2 Displays Unit of Measure 3 Arrow not used 4 Preset batch quantity 5 History icon not used 6 Auto is an indicator of unit being in Auto Batch Mode 7 Low battery ico...

Страница 5: ...nd move towards the pump 1 Close fluid dispense valves at every position 2 Once the main fluid outlet valve at the pump is closed and the air pressure to the pump motor is properly adjusted the air va...

Страница 6: ...n shutoff valves Start the pump to pressurize the system 4 Before use to ensure accuracy purge all air from the fluid lines and dispense valve s Figure 5 Tighten nozzle with wrench METER OPERATION NOT...

Страница 7: ...NS These functions operate the same in Manual Mode and Auto Batch Mode Re settable and Accumulated Totals The meter has two flow totalizers Re settable Total and Accumulated Total 1 Press and hold TOT...

Страница 8: ...OTE N Changing the batteries does not affect any of the programmed values or totals Figure 10 Replacing the batteries CHANGE FACTORY SETTINGS Each meter is calibrated at the factory for use with motor...

Страница 9: ...o 0 3 Press RESET to advance to the next digit in the scale factor 4 Repeat steps 2 and 3 for all five digits Scale factor digits Figure 13 Scale factor display Save Changes To save changes and exit p...

Страница 10: ...y shows 4 00 You get an error factor of 1 05 4 The existing Scale Factor is 1 0123 as shown in steps 1 and 2 in Verify Changes 5 To calculate a new factor 1 0123 existing Scale Factor x 1 05 error fac...

Страница 11: ...utlet connections 1 2 in NPT 1 2 in BSPP Minimum and maximum flow range will vary with fluid viscosity Table 4 Part numbers inside meter PARTS 1 2 Figure 16 Parts back of meter Figure 17 Parts front o...

Страница 12: ...Trademarks appearing in this document are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product...