Temperature limits of heat conveying liquid:
32…194° F (0 1…90° C)
Custom-made, wall-mounted electronic unit:
32…266° F (0 1…130° C)
Length of the connecting cable between the flow sensor and electronic unit:
4 ft (1 2 m)
Custom-made:
8 ft or 16 ft (2 5 m or 5 0 m)
Maximum admissible working pressure (nominal pressure PN):
232 psi or 363 psi (16 bar or 25 bar)
If the flow rate exceeds the maximum value q
s
:
• When the flow rate < 1 2∙q
s
, the flow rate measurement and calculations are continued;
• When the flow rate > 1 2∙q
s
, calculations are performed using flow-rate value 1 2∙q
s
, the error “exceeded maximum flow
rate” is recorded and the duration of that error is calculated
Pulse Inputs (Additional)
• The number of pulse inputs:
2
• Indicated
units:
m³
• Pulse
value:
programmable
• Input pulse types:
IB according to LST EN1434-2
• Max permissible frequency of input pulses:
3 Hz
• Max permissible voltage of input pulses:
3 6V
• Condition of maintenance of high level:
3 6V through 3 3 MΩ resistor
• If the meter is ordered with the "pulse input-output" function, then a permanently connected 1 5 m long cable is fitted in
the meter for connecting the inputs-outputs
Temperature Measurement
Temperature measuring range:
32…194° F (0…90 °C)
Custom-made:
32…266° F (0…130 °C)
Temperature difference measuring range:
2…70 K or 3…70 K
Custom-made:
2…110 K or 3…110 K)
Temperature sensor design:
• DS type according to LST EN1434-2 (when the flow sensor connection type is G3/4, G1 or G1-1/4),
• PL type according to LST EN1434-2 (for other flow sensor connection types)
Connected cable length:
Up to 33 ft (10 m)
Display
• A liquid crystal, 8-digit display for the representation of the values of the indicated parameter and for the representation of
parameters, units of measurement, and
Operating Modes
with special symbols
• Integral and instantaneous measured parameters as well as data read from the meter archive and configuration
information specified in
"Operating Procedure" on page 15
are displayed
Energy measurement units (user-selectable when installing):
kWh, MWh, Gcal or GJ
Resolution of energy indicators (user-selectable when installing):
0000000 1 kWh
00000001
kWh
00000 001
MWh
(Gcal
or
GJ)
000000 01
MWh
(Gcal
or
GJ)
Resolution of flow-rate indicators:
00000 001 m³
OTEE:
N
If battery is discharged or disconnected, all integral readings and archive data are saved for at least 15 years and can
be accessed by connecting a power battery in the
Operating Mode
Technical Specifications
Page 47