Programming
Page 38
May 2020
DSY-PM-01378-EN-08
Reset Password
The reset password parameter restricts resetting the totals on the monitor� The
Password
must also be set to restrict the total reset� Initially, the password is set to all zeros and any
user can reset the stored totals on the monitor� To change the password, press
ENTER
at
the
RstPswd
prompt� The first digit flashes� Press
UP
to increment the digit and
RIGHT
to
advance to the next digit� After entering all digits, press
ENTER
to store the password
and return to the
Fluid
parameter� The reset password is now required to reset the totals on
the monitor�
OTE:
N
Entering a password in the
Passwd
screen and leaving the password blank in the
RstPswd
screen allows for total resets (not requiring a password), but restricts
programming modification�
Gas
Operating Pressure
At the
Op Pres
prompt, press
ENTER
� The first digit of the current pressure setting flashes� If
the current selection is correct, press
ENTER
to advance to the next parameter� To change
the operating pressure, press
UP
to increment the digit until it matches the first digit of the
correct pressure value� Press
RIGHT
to move to the next digit� When all the digits have been
entered, press
ENTER
to advance to the
Op Temp
parameter�
Operating Temperature
At the
Op Temp
prompt, press
ENTER
� The first digit of the current temperature setting
flashes� If the current selection is correct, press
ENTER
to advance to the next parameter�
To change the operating temperature, press
UP
to increment the digit until it matches the
first digit of the correct pressure value� Press
RIGHT
to move to the next digit� When all the
digits have been entered, press
ENTER
to advance to the next parameter�
In
Programming
mode the monitor advances to the
PulsOut
parameter, see
In
Extended Programming
mode, the monitor advances to the
Damping
parameter, see
Save Settings and Return to Run Mode
After entering all parameters, press
MENU
� Saving displays on the menu, followed by
a blank screen and then the firmware version number� The monitor then returns to
Run
mode�
IMPORTANT
Settings are not saved until after manually saving with the
MENU
button.