Monoxor
Plus Manual
Configuration
0019-9370 Rev 1
17
3.4. Ambient CO Menu
Ambient CO
Function
Access the Ambient CO Menu.
When initiated, the Ambient CO feature monitors CO
values continuously and captures a reading every
minute for 15 minutes (a total of 16 readings from t
0
to t
15
).
Press ENTER to initiate the Ambient CO test. This
begins a 15-minute test cycle, during which a status
screen is displayed. It shows the starting ambient CO
value, the current CO value, and the elapsed time into
the test.
NOTE:
Press the F2 key to cancel a test
in progress.
After the test is complete, the Ambient CO Summary
screen is displayed. This is a scrollable window that
shows the 16 CO “snapshot” readings, as well as the
maximum CO reading that was sampled during the
entire test.
NOTE:
The Max CO Reading is the highest
sampled CO reading – even if the reading
was taken in between one of the sample
“snapshot” readings.