background image

DIOXOR

   

II

INSTRUCTION 19-9121

Portable SO

2

 Analyzer

Part No. 19-7038 & 19-7043

Rev. 5 - September 1997

®

Bacharach, Inc.

625 Alpha Drive, Pittsburgh, PA 15238

(412) 963-2157/2164   Fax: (412) 963-2640

Web: www.bacharach-inc.com

Printed in U.S.A.

® Registered Trademarks

Содержание DIOXOR 19-7038

Страница 1: ...9 9121 Portable SO2 Analyzer Part No 19 7038 19 7043 Rev 5 September 1997 Bacharach Inc 625 Alpha Drive Pittsburgh PA 15238 412 963 2157 2164 Fax 412 963 2640 Web www bacharach inc com Printed in U S...

Страница 2: ...such as electrochemical sensors are warranted for a period of six months THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF I ANY AND ALL OTHER WARRANTIES EXPRESS ORIMPLIED...

Страница 3: ...be obtained before use Assistance is available by calling your nearest Bacharach Service Center 1 INTRODUCTION The Dioxor II is a commercial grade portable instrument designed to display concentratio...

Страница 4: ...escribed in the following paragraphs For your convenience and to ensure that the instrument will provide reliable SO2 indica tions the SO2 sensor is installed and the instru ment calibrated on a known...

Страница 5: ...n the Knurled Nut 03 2023 then add 1 4 turn to snug probe to the rest of the probe assembly NOTE In order to prevent the possibility of misplacing the Front 03 2024 and Back 03 2025 Ferrules loosen bu...

Страница 6: ...ove the batteries and ensure that the POWER switch is OFF The OFF position places a short across the SO2 sensor thus keeping the sensor from being destabilized while not in use 4 2 Zeroing the Instrum...

Страница 7: ...of 025 ppm 4 3 Backlight ON OFF The LCD can be read in low light areas by setting the front panel LIGHT switch to ON The backlight stays on until turned off or until the POWER switch is set to OFF 4 4...

Страница 8: ...conditions 4 7 Long Term Storage When storing the Dioxor II for extended periods of time set its POWER switch to OFF and remove the batteries The POWER OFF positionplacesashortacrosstheSO2 sensor thu...

Страница 9: ...Bacharach S S Center 7300 Industrial Park Rt 130 Bldg 22 Pennsauken NJ 08110 609 665 6176 609 665 6661 FAX Bacharach S S Center 5151 Mitchelldale B 4 Houston TX 77092 713 683 8141 713 683 9437 FAX 7...

Страница 10: ...ion of the nose and throat choking sneezing coughing and broncho spasm Severe overexposure may cause death through pulmonary edema abnormalfluidbuildupinthelungs orfromrespiratoryarrest Prolonged or r...

Страница 11: ...cult Seek medical attention immediately References 1 Code of Federal Regulations Title 29 CFR Parts 1900 1910 Labor Superintendent of Documents U S Government Printing Office Washington DC 20402 2 Thr...