SLING PSYCHROMETER 

Configuration  

  Operation  

  Maintenance 

Part Number:  0012-9015 

November 2017, Rev. 7 

 

For Use with Spirit Thermometers 

P/N 0012-7012 

(30° to 110° F, Red Spirit) 

P/N 0012-7043  

(

–5° to 50° C, Blue Spirit) 

Discontinued Mercury Thermometers 

P/N 0012-7011 

(30° to 110° F, Mercury) 

P/N 0012-7013 

(

–5° to 50° C, Mercury) 

 
 

 

 
 

 

 

 

 

 

CAUTION: Damage to thermometers or 

plastic case will result if instrument is 

exposed to direct sunlight or excessive  

heat for prolonged periods. 

 

 

WARRANTY

 

Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material 
and  manufacture  and  will  conform  substantia

lly  to  Bacharach Inc.’s  applicable  specifications.  Bacharach’s 

liability and Buyer’s remedy under this warranty are limited to the repair or replacement, at Bacharach’s option, 
of this Product or parts thereof returned to Seller at the factory of manufacture and s

hown to Bacharach Inc.’s 

reasonable satisfaction to have been defective; provided that written notice of the defect shall have been given 
by Buyer to Bacharach Inc. within one (1) year after the date of delivery of this Product by Bacharach, Inc. For 

full details concerning this warranty, contact Bacharach Inc. 

 

Product Leadership  

  Training  

  Service  

  Reliability 

Содержание 0012-9015

Страница 1: ...ivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc s applicable specifications Bacharach s liability and Buyer s remedy under this warranty are limited to the repair or replacement at Bacharach s option of this Product or parts thereof returned to Seller at the factory of manufacture and shown to Bacharach Inc s reasonable satis...

Страница 2: ...s H Thermometer clips I Roll pin 2 Fill psychrometer reservoir with water Replace cap B 3 Be sure wick covers wet bulb The other bulb is dry 4 Pull body C from tube E until body hangs free 5 Use tube E as handle whirl body C about 1 minutes 6 Read wet and dry bulb thermometers replace body in tube 7 Set thermometer readings on upper two calculator scales 8 Read relative humidity as indicated by ar...

Страница 3: ...e temperatures The range of the psychrometer is from 10 to 100 R H for dry bulb temperatures of 30 to 100 F 5 to 50 C In addition to the above instructions barometric pressure and other factors will influence exact relative humidity determinations to a very minor degree For precise work use a psychrometric chart or set of tables such as W B No 235 Psychrometric Tables for Obtaining the Vapor Press...

Страница 4: ...6 5456 Cap 1 1 1 1 0012 0012 Friction Ring 2 2 2 2 0012 0194 Body F 1 1 0012 0018 Body C 1 1 0012 0006 Tube F 1 1 0012 0019 Tube C 1 1 0012 0266 Thermometer 30 to 110 F Red Spirit 2 2 0012 0327 Thermometer 5 to 50 C Blue Spirit 2 2 Part Number Description Qty 0012 0011 Wick Replacement Kit containing 4 Wicks Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 USA Pittsburgh PA USA Dublin ...