T405S Indicator Service Manual
81
7.1
SMA Protocol
7.1.2 Standard Scale Response Message
<LF><s><r><n><m><f><xxxxxx.xxx><uuu><CR>
<LF>
Line feed
Start of the response message.
<s>
Scale Status
‘Z’ Center of Zero
‘O’ Over Capacity
‘U’ Under Capacity
‘E’ Zero Error
‘T’ Tare Error
<space> None of the above conditions.
<r>
range
Multi-interval range. Always ‘1’ if multi-interval is
disabled.
<n>
gross/net status
‘G’ = Gross weight
‘T’ = Tare weight
‘N’ = Net weight
<m>
Motion status
‘M’ = scale is in motion
<space> = scale is stable
<f>
Future use
<space> = always a space.
7.1.3 Unrecognized Command Response
<LF>?<CR>
7.1.4 About Command Response
The ‘A’ and ‘B’ commands are used together to get all of the scale about data. The ‘A’
command will always return the 1st response below. The ‘B’ command must be sent
multiple times to get the 2nd, 3rd, and 4th responses. Once the 4th response is
received, the next ‘B’ command will return an Unrecognized Command Response. At
this point you would have to send another ‘A’ command to get the 1st response again.
<LF><xxx>:<yyyyy><CR>
1st response:
<xxx> = “SMA”
<yyyyy> = compliance level/revision
2nd response:
<xxx> = “MFG”
<yyyyy> = manufacturer
3rd response:
<xxx> = “MOD”
<yyyyy> = software part number
4th response:
<xxx> = “REV”
<yyyyy> = software revision
Содержание T405S
Страница 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Страница 2: ...BTEK_T405S_s_en_501638 book...
Страница 8: ...8 T405S Indicator Service Manual...
Страница 134: ...134 T405S Indicator Service Manual...
Страница 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Страница 150: ...150 T405S Indicator Service Manual...
Страница 154: ...154 T405S Indicator Service Manual...
Страница 155: ......
Страница 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...