![B meters MAG Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/b-meters/mag/mag_instruction-manual_3072628025.webp)
25
MAG
User Manual v2.0
4.3.3 Negative pressure
Avoid vacuum conditions in the pipe. These can damage the coating of the flowmeter and move the
electrodes from their correct position.
4.3.4 Protection from direct sunlight
Protect the flowmeter if exposed to direct sunlight.
4.3.5 Operating temperatures
• For normal and efficient operating of the flowmeter:
» The room temperature must be limited within the range of (-25 ÷ +60) °C, (-13 ÷ +140) °F.
Fig. 23 | Avoid direct exposure to sunlight
Fig. 24 | Environment and fluid temperature limits
°C
°F
Min.
Max.
Min.
Max.
Coating in EBONITE
-40
+80
-40
+176
Coating in PTFE (remote)
-40
+130
-40
+266
Coating in PTFE (compact)
-40
+80
-40
+176
Coating in PTFE (separate high temperature)
-40
+180
-40
+356