B.M.P. DYNAMICROLL FOOD INOX Скачать руководство пользователя страница 1

Operating instructions 

Use and maintenance manual 

    

               B.M.P.  S.r.L. 
      INDUSTRIAL RAPID DOORS 

 

Web site : 

www.bmpitalia.it

   e-mail : 

[email protected]

 

 

 
 
 

 

 

USE AND MAINTENANCE 

MANUAL 

 
 
 

 

 
 
 
 
 
 

      UNI EN 13241-1 : 2 

 

 

 

Read

 

this

 

manual

 

carefully

 

before

 

installing

 

the

 

product.

 

 

The

 

service

 

of

 

installation

 

must

 

be

 

performed

 

only

 

by

 

authorized

 

personnel

 

and

 

in

 

accordance

 

with

 

national

 

wiring

 

standard.

 

 

After

 

reading

 

the

 

entire

 

manual,

 

keep

 

it

 

for

 

future

 

reference.

 

 

IMPORTANT 

ENGL

ISH

DYNAMICROLL® FOOD INOX 

Содержание DYNAMICROLL FOOD INOX

Страница 1: ...lia it USE AND MAINTENANCE MANUAL UNI EN 13241 1 2 Read this manual carefully before installing the product The service of installation must be performed only by authorized personnel and in accordance with national wiring standard After reading the entire manual keep it for future reference IMPORTANT ENGLISH DYNAMICROLL FOOD INOX ...

Страница 2: ...d EN 13241 1 2003 certified with the system 3 By the institute notified CSI specific 0497 It i salso in line withthe safety reqiurement specified by machinery derective 98 37 CE with particular reference to the disposition UNI EN 292 1 e 2 Machine safety Fundamental concepts general designed principles CEI EN 60204 1 Machine safety Electrical equipment of machines part 1 general rules CEI EN 13241...

Страница 3: ...orized person ASSISTANCE DESCRIPTION Tick the box corresponding to the operation performed Describe any risk and incorrect use Installation Maintenance Repair Changes __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ _____________________________...

Страница 4: ... on an exinting door to improve motorized operation Owner natural or legal person that has the door and that is responsible for its operation and use Maintenance all operation check lubrification cleaning ecc sufficient to ensure correct and safe operation of the door and its component after installation Maintenance includes adjustements repair or replacement for usury or accidental distruction of...

Страница 5: ...show warnings and safety massage and should not be removed or damaged The importance is so classified ATTENTION This symbol indicates the possibility of death or serious injury WARNINGS This symbol indicated the possibility of injury or damage ATTENTION Do not disassemble or try to repair the door Contact service center The door must be grounded This will prevent fire or electric shock Keep away f...

Страница 6: ...ide the manual Cut risk During door installation Istruction inside the manual ELETTRICAL RISK Elettric shock risk Elettrical transmission comply with the rules MATERIAL AND PRODUCT RISK Risk to contact or inhalation of harmful fluids gases mists fumes and dust Not present Dangerous poses or ecces strain Not present The sound pressure level produced by the industrial door was measured and valued si...

Страница 7: ...PVC curtain 9 Motor cover 10 Polyzene guides 11 Side plate 12 Ball bearing 13 Shaft 14 Roller tube 15 Pulley 16 Toothed belt 17 Limit switch 18 Limit switch support 19 Adapter 20 400 V tree phase motor 21 Adapter support 22 Key 23 Drive shaft 24 Edge cogged curtain DESCRIPTION OF COMPONENT 3 2 1 4 5 7 8 9 10 11 12 13 14 15 22 16 18 12 11 24 19 21 23 20 17 ...

Страница 8: ...ol board 13 Shaft 22 400 V tree phase motor 4 Column 14 Ruler tube 23 Adapter support 5 Crossbar 15 Pulley 24 Cogwheel 7 porthole 16 Toothed belt 25 Chain link 8 PVC curtain 17 Limit switch 26 Chain 9 Motor cover 18 Limit switch support 27 Key 10 Polyzene guides 19 Shaft key 28 Shaft 11 12 13 14 3 2 1 4 5 7 8 9 10 11 14 15 16 17 18 19 20 21 22 23 24 25 12 26 27 28 ...

Страница 9: ... the thickness of the cable conforms to what is stated in the specification of the power source Never install a differential circuit breaker in wet or damp areas EQUIPMENT NEEDED 1 Flexometer 10 Level 2 Suitable lifting equipment stairs elevator ecc 11 Set of allen keys 17 mm 13 mm 10mm 8 mm 3 Screwdriver set 12 Tester 4 Iron drill 13 Hammer 5 Hammer drill 14 Cordless screwdriver 6 Drill bits iron...

Страница 10: ...r controls the operating current of the motor and the heat sink temperature providing to report any malfunction All imputs are indicated by leds Allarm messages are indicated by flashing light or display WARNING Accessories output 24Vac 300mA MAX output 12Vdc 100mA MAX LEGENDA 1 CONTROL CARD 6 MOTOR BRAKE TERMINAL N 30 31 FLASHING LIGHT N 29 30 2 METAL BOARD 7 CONTROL BOARD LOCK 3 MOTOR TERMINAL U...

Страница 11: ... Brake RD TERMINA mper inputs N C 0mA max 0mA max tion in use 20 tion in use 40 ntijamming se mmand g standard tart puts 12Vdc puts 12Vdc opening limit s closing limit sw it switch switch er accessories er accessories tion in use 20 3 C ase ase ase hase eutral ng terminal ght 230V OMMON flashin 120V AL WITH LIM N C not used CONNECTIO 0 300 opened 0 300 closed d nsor N C closing optio switch witch ...

Страница 12: ...n encoder yellow ot used ot used 4 Vac power acc 4 Vac power acc IGNAL option l Motor pha Motor pha Motor pha Power ph Neutral Groundin Flashing li Phase CO Brake ARD TERMI mper inputs N A max encode A max encode n in use 20 300 mming sensor nd andard closin 12Vdc 12Vdc cable w cable cessories 300mA cessories 300mA n in use 20 300 C ase U ase ase hase 230Vac ng terminal ght 230V OMMON flashin 120V...

Страница 13: ...nterrupted A safety sensor near roller tube it controls curtain wrapping and it stop the curtain if during the closure curtain support on an obstacle CONTROL CARD OPERATION MODE AUTOMATIC CLOSING ADJUSTABLE This system allow to open the door with START command and adjustment of pause time for automatic closing To enable this mode of operation position the dip switch 1 on ON Factory mode operation ...

Страница 14: ... the maintenance staff ORDINARTY CLEANING AND MAINTENANCE The ordinary maintenance operations are all the operations that could do the user The maintenance and clearing of the door are necessary to obtain the best functioning higher safety for the user and a longer operativeness of the door COMPONENT DESCRIPTION PERIODICITY Structure Verify that the structure is correctely fixed to the wall in ord...

Страница 15: ... Six month Mechanical components Verify the condition of the motor Control the condition of the motor brake Control the wear and tension of the drive cjhain of the motor adapter Control the condition of the reducer oil leak fixing to the motor fixing of the structure Control the condition of the limit switch wear of the beltwheel wear and fixing of the pulley the correct functioning of the camme a...

Страница 16: ...BLE PHOTOCELL with encoder 3 RELEASE THE STOP BUTTON LED 6 turned ON 3 MOVE THE DOOR WITH BUTTON P1 AND P2 OF 40 50 CM AND LOCATE IT ON CLOSE POSITION this operation is useful to recognize the encoder 3 VERIFY THAT THE LED LD13 radio safety edge or sensor in the upper case IS ON 3 IF NOT MAKE JUMPERS 7 13 AND CONTROL THEN THE SECURITY COMPONENTS 3 INVERT THE ENCODER CABLE yellow with green 3 FOR D...

Страница 17: ...esistive band is perfectly flat for all the length of the black profile or take out the gum and control the 5 VERIFY THE CONNECTIONS OF THE RECEIVER 6 THE PHOTOCELL DOESN T WORK LD 7 OFF 6 VERIFY THE ALIGNMENT 6 VERIFY THE CONNECTION OF THE BLACK RECEIVER CABLE brown 12Vdc blue 0V dc black signal that it arrives to the terminal 14 in the local plant the door doesn t close 6 VERIFY THE CONNECTION O...

Страница 18: ...EASE THE INTERVENTION TIME OF THE ANTI JAMMING PHOTOCELL USING THE PROGRAMMER PARAMETER SETTING ANTI JAMMING PHOTOCELL READING 10 LOWER THE ANTI JAMMING PHOTOCELL SENSOR 11 LD1 REMAINS ON IN THE TOP LEFT HAND 11 VERIFIY THE FUSE 11 THE CARD IS DAMNAGED replace it 12 THE DOOR DOESN T CLOSE AUTOMATICALLY 12 VERIFY DIP 1 ON automatic OFF manual 12 CONTROL THE CORRECT FUNCTIONING OF THE SAFETY COMPONE...

Страница 19: ... 5 kw can t be higher than 9A control when the door s working if the door exceeds the threshold lower the opening HZ 14 THE PHOTOCELL DOESN T WORK 14 CONTROL THAT IN THE VICINITY THERE AREN T ANY OTHER PHOTOCELLS THAT COULD CAUSE REFLECTION try to darken the photocells the door closes but the photocell doesn t reverse the curtain 14 CONTROL THAT WITH THE PHOTOCELL CABLES THERE AREN T ANY HIGH VOLT...

Страница 20: ...ear and tear to weathering The replacement the addition or the modification without the permission of the manufacturer the use of component not identical to those provided or any other brand will void the warranty The responsibility for B M P S r L remains however limited to the repair or replacement of defective parts B M P S r L disclaim any responsibilityfor any consequence or damage caused fro...

Страница 21: ...e of problem you have sendto the manufacturer in these ways mail assistenza bmpitalia it fax 0173 658336 web www bmpeurope eu Information neded Personal information company or owner of the door Door data serial NO Description of the problem Eventually photos REPAIRING REQUEST ...

Отзывы: