background image

© b-intense

®

 

Version 01/2021

Made in Austria

INFRAROTKABINEN

DE

FR

EN

NL

inkl. Anschlussplan der b-control Steuerungen

incl. installation manual of the b-control units
avec instructions de montage des systèmes de commande b-control
incl. montagehandleiding b-control besturingsinrichtingen

Bedienungsanleitung 

b-intense

®

 Infrarotkabinen

Operating Instructions 

b-intense

®

 infrared cabins

Manuel d’utilisation des cabines  

à infrarouges b-intense

®

Gebruiksaanwijzing b-intense

®

  

infraroodcabines

230 Volt

Содержание b-control deluxe

Страница 1: ...he b control units avec instructions de montage des systèmes de commande b control incl montagehandleiding b control besturingsinrichtingen Bedienungsanleitung b intense Infrarotkabinen Operating Instructions b intense infrared cabins Manuel d utilisation des cabines à infrarouges b intense Gebruiksaanwijzing b intense infraroodcabines 230 Volt ...

Страница 2: ...36 EN ...

Страница 3: ...ion of b intense infrared cabins 47 Operation of the b control units 49 Effects of wellness supplements 50 b intense moments App and Bluetooth function 51 Infrared programs 59 Cleaning and care of the b intense infrared cabin 60 Maintenance instructions 60 Disposal of the b intense infrared cabin 61 Certificate of Warranty 61 Declaration of conformity 63 Annex ...

Страница 4: ...gy The b intense infrared heater especially developed and designed by b intense is not comparable with conventional infrared technologies With this patented technology we offer our customers the effective and full spectrum health promoting effect in long studied and independently tested composition Due to the particular innovation of the spliced high quality protective glass the b intense heater i...

Страница 5: ...ed cabin and consult a professional engineer to repair the damage or to replace parts of the system Observe safety instructions before use Store and operate in a dry environment Humidity must not excel 60 Not condensing Safety Warning Never cover an infrared heater Make sure that the heater is not covered and no items are put on it Covering the infrared heater may cause a fire hazard Follow all sa...

Страница 6: ...t not be operated on a multiple socket fire hazard 5 If used commercially a professional annual check of the electrical installation must be ensured by the operator Only original b intense component parts are safe for use The use of not certified components can lead to damages or injuries Waranties and guarantees expire with the use of not certified components Plugging the cabin in and out is only...

Страница 7: ...ren are not allowed to play with the device or to carry out any cleaning or maintenance work Persons with limited sensation of heat persons under the effects of alcohol drugs tranquilizers are not allowed to use the cabin Consult your doctor independently concerning your infrared treatment after operations in case of illness injuries pregnancy or in the case of plastic or medical implants as well ...

Страница 8: ...needs of children and adolescents by the supervising adult Adjust the headrest so the radiation doesn t impact the back of the head directly Special note Red back A distinct redness in the exposed back area ist normal and desired and happens due to the increased blood circulation If the redness is still visible more than 3 hours after application reduce the radiation intensity or the duration of u...

Страница 9: ...iator and lean back Usually sweating starts after 10 15 minutes Adjust the neck support so that the radiation does not hit the back of your head directly Regulate the b intense infrared heater intensity and adjust the additional features according to your needs via the control unit The b intense infrared control units offer pre installed user programs e g back heatload or slim See detailed descrip...

Страница 10: ...h b intense licensed components b intense is not liable for any damage occuring through unintended use The risks of unintended use lie within the operator user General safety guidelines and use of the b intense Read the Operation Manual thoroughly including the medical acvide Always check the b intense cabin for visual damage Ensure the conformity of the electric connection with the specification ...

Страница 11: ...notices and application notes for your own safety Medical mode of action Infrared radiation IR radiation is part of the electromagnetic spectrum The most important natural source of IR radiation is the sun about 54 of the solar radiation reaching the earth s surface is IR radiation In addition the human skin is increasingly exposed to artificial IR sources in the cosmetic and wellness sector but a...

Страница 12: ... impaired In the case of extensive scars too little heat may also be dissipated due to the reduced vascular supply Special caution is also required in the case of diseases which lead to increased metabolic activity and thus increased heat generation status epilepticus malignant hypertermia Scars in the applicated area should therefore be covered Since the DNA repair mechanism may be impaired we ad...

Страница 13: ...minutes Current cabin interior temperature in Degrees Celsius Operation of the b control units Starting up your b intense infrared cabin Press the power button for 1 second to activate your b intense infrared cabin By switching on the following basic settings are auto matically activated The back and front heater active within 2 3 seconds The front heater heats up to 80 of its output the back heat...

Страница 14: ...n once to reach the menu of the b intense infrared programs For operation see more on page 51 Press the button several times to choose between the functions ON AUTO OFF The AUTO function activates the fan as soon as the internal temperature of the cabin exceeds 40 C Press the button once to activate the LED coloured light select the preferred colour with Press the button once to activate Music Pla...

Страница 15: ...fects are prominent in the b intense infrared cabin The b intense colour light offers different options to choose from Our recommendation Choose only one colour per infrared application to achieve the best result VIOLET for creativity meditation BLUE for energy vitality Tip Use the colour blue especially in the morning RED for relaxation peace Tip Definitely use the colour red for application righ...

Страница 16: ...etooth Low Energy BLE need access to your location information We ensure not to process or use information on your location for other purposes Functions on the home screen Your home screen gives you an overview of the functions of your cabin The features of the control unit in the cabin are represented on the home screen and can mostly be operated directly In the operation instructions of your cab...

Страница 17: ...y Please share your experiences with us and send us an email to office b intense at Description of the b intense infrared programs Heatload Duration 15 minutes Light colour blue The program heat load is an optimal preparation for sports or subsequent treatment for example massage The relatively short intense heat input is an adrenergic stimulation activates and provides heat to the distribution in...

Страница 18: ...timuli aims at mild heating of the body shell soothes and relaxes The focus is on a detonisation of the muscular structure and an improvement in tissue repair This program is suitable after sport as well as in the evening After a long especially physically strenuous day this program is especially recommended to let go and relax We rec ommend changing to red light in the evening 0 10 20 30 40 50 10...

Страница 19: ...ms determined by infrared experts and increase the effectiveness of your time in the b intense cabin Always remember that you should adjust the radiator as individually as possible In case you do not want to use a program adjust the intensity as desired at any time Creating an individual program via b intense moments app Duration up to 60 minutes Light colour freely selectable Your program is not ...

Страница 20: ...and you enter the selection menu of the b intense infrared programs Choose between preheating 15 and preheating 30 and enter with the program button Status display The display changes automatically to the status display of the PREHEARTING program Remaining time of the program Current temperature in the cabin Warning message DO NOT USE Finishing the program PREHEATING After reaching a temperature o...

Страница 21: ...ogram and informs you about Name of the program Remaining time of the program Current intensity of the back heater in the program progress Current temperature in the cabin only for b control deluxe Adjustment of intensity course of the program 20 20 0 Example of the program status display Example of the status display for an user defined program created in the b intense moments App Note b intense ...

Страница 22: ...d to the remaining seat Programs selection in a 2 person cabin In a 2 person cabin you can choose a different program for each seat Thus you can enjoy the heat for two the program is however tailored to your needs Program status display The display shows you the current status of the chosen program and informs you about Name of the program Remaining time of the program Seat assignment for the prog...

Страница 23: ...ntrol unit They can only be selected via the device on which you have instal led the app If you select your individually created program via tablet or mobile phone the name Custom appears on the display of the control The remaining parameters are shown as usual Ending the program You can always end your user program Press the On Off button for this purpose The program ends and the back heater is s...

Страница 24: ...ets back to the program status display 10 seconds after the last button was pressed Chaning the b intense infrared programs You can end or change an infrared program at any time To do this select the program at your user seat with the program symbol and press the ON OFF button The user program is ended To select another program press the program symbol select a suitable infrared program and confir...

Страница 25: ...ds a mild lukewarm soap sud Cabin walls b intense recommends a mild lukewarm soap sud Cabin ceiling and floor b intense recommends a mild lukewarm soap sud Glass b intense recommends a standard glass cleaner without special features Metal components b intense recommends a mild lukewarm soap sud Use a lint free microfiber cloth for cleaning Never use abrasive or pungent detergents Disconnect the b ...

Страница 26: ... the control panel Infrared heaters Before cleaning ensure that the infrared heaters have cooled down completely Wet a microfiber cloth with a glass cleaner to clean the infrared heaters Dry the surface with a dry microfiber cloth Never wet clean the infrared heaters Maintenance instructions The b intense infrared cabin requires no special maintenance The infrared lamps are not subject to aging an...

Страница 27: ...tee for professionally installed replacement parts corresponds to that of the original warranty provided for the functioning of the cabin parts from the date of purchase In addition the minimum provisions apply under the statutory warranty from the date of installation Proof of purchase of the equipment must be provided with any claim under the guarantee by presenting the original receipt delivery...

Страница 28: ...rior to infrared application Printing and typesetting errors excepted KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE AND HAND THEM OVER WITH THE B INTENSE INFRARED CABIN IF THERE IS A CHANGE OF THE USER OR OWNER Do not hesitate to contact us for further questions Your b intense team b intense GmbH branch office of CB Capital Beteiligungs GmbH Am Jungfernberg 17 A 2201 Gerasdorf by Vienna Austri...

Страница 29: ...ollowing recommendations for installation and storage The cabin must be stored and installed indoors The ambient temperature of the b intense infrared cabin should be at least 18 C room temperature and at maximum 35 C The optimal humidity should not exceed 60 If this is not possible suitable ventilation of the space to be used must be arranged The cabin must be protected from any direct water spra...

Страница 30: ... nails or screws sticking out the cabin should stand stable and not loose Visually check the b intense infrared cabin regularly In case of visible damage unplug the b intense from the power supply and contact us via office b intense at Before working on the controller the power supply must be switched off on all poles pull the main plug and prevented it from being switched on The use of components...

Страница 31: ...ailable for option for all senses the 3 5 mm jack socket on the back of the control unit must be connected to the AUX input of the control box using the enclosed cable 6 Connect the temperature sensor cable into the intended socket 7 Connect the plugs for the cabin floor heating available for option warm feet on the base plate and link the connection to the control box using the intended plug 8 Co...

Страница 32: ...c b control single controls Dimensions of power module 310 x 200 x 50 mm Dimensions of control unit front 220 x 92 mm Cut out for the control unit 215 x 82 mm depth 20 mm Power module Protection class 1 protection type IP20 Mains supply 230 VAC 50 60 Hz max 2500 Watt protection at least 13A max 16A FI circuit breaker with trip current 30 mA recommended Reserve output 230 VAC max 2 A activated and ...

Страница 33: ...ater Fußwärme Foot Mat FRONT FRONT Sonnenlicht max 5A Farblicht RGB Ledstreifen Ledstreifen weiss B G R Lautsprecher Re Li Temperaturfühler PT1000 Lüfter 12V Rückseite AUX Eingang W Weisslicht Connection plan b control deluxe Annex temperatur sensor back AUX input speaker LED light RGB LED light white Sonnenlicht sunlight white light coloured light fan ...

Страница 34: ...LINKE Seite LEFT Side RECHTE Seite RIGHT Side REAR BACK IR Strahler Heater IR Strahler Heater IR Strahler Heater IR Strahler Heater Fußwärme Foot Mat FRONT FRONT Power Supply 6 Annex Connection plan b control basic ...

Страница 35: ...FT Side RECHTE Seite RIGHT Side REAR BACK IR Strahler Heater IR Strahler Heater Power Supply 115 230VAC 60 50Hz nicht belegt not conected nicht belegt not conected nicht belegt not conected Annex Connection plan b control single ...

Отзывы: