DRT-430A series User Manual

 

                                                                                                                                                                                                                                                 
 

 

 

DRT-430A 

Three phase four wires DIN rail energy meter LCD display

 

(Four modules 

 MID certificated) 

 
 
 
 
 
 

 
 
 

1.1        Foreword 

1.2        General Technical Data 

1.3          Basic errors 

1.4        Dimension 

1.5   

       

Installation 

1.6        Operating 

1.7        Technical support   

 

 

User manual 

Содержание DRT-430A

Страница 1: ...RT 430A Three phase four wires DIN rail energy meter LCD display Four modules MID certificated 1 1 Foreword 1 2 General Technical Data 1 3 Basic errors 1 4 Dimension 1 5 Installation 1 6 Operating 1 7 Technical support User manual ...

Страница 2: ...aler immediately All energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim for warranty Therefore NEVER open meter by yourself or break the seal of the energy meter The warranty time is 12 months after installation and only valid for construction faults 1 2General Technical Data 1 2 1 Voltage V Voltage AC Un 3 230 400 Voltage rang 3 161 279 to 300 5...

Страница 3: ... 2uS waveform 1 2 13 Current withstand 30Imax for 0 01s 1 2 14 Pulse output rate 1000imp kWh 1 2 15 Data stored more than 20 years when power is off only LCD version 1 2 16 Mechanical and EMC environments The meter is intended to be installed in a Mechanical Environment M1 with Shock and Vibrations of low significance as per 2014 32 EU Directive The meter is intended to be installed in Electromagn...

Страница 4: ... 430A series User Manual 1 4 Dimension Height 110 mm Width 70 mm Depth 64 5 mm Weight 0 4 kg net Material Front panel PC inflammable retarding Cover ABS inflammable retarding Base ABS inflammable retarding ...

Страница 5: ...alled indoor directly or in a meter box which is waterproof outdoor subject to local codes and regulations To prevent tampering secure the meter with a padlock or a similar device The meter has to be installed against a wall which is fire resistant The meter has to be installed in a good ventilated and dry place The meter has to be installed in a protection box when placed in dangerous or dusty en...

Страница 6: ...hase B L3 indicator it will become red when there is current in phase C The other indicator is for pulse output When consumption happens the LED will flash and display red The more quickly LED flash the more consumption there is Reading the meter The display digit of DRT 430A is 6 1 Six integers are marked with white color and one decimal is marked with red Display function It will display the tot...

Страница 7: ...ply inside the meter Is the operating power too low Maybe there is a fault in the inside circuit Check that the power supply If the operating power is too low the spacing interval of the pulses will take some more time this is why it seems like the meter won t count Please contact your technical supporter to replace this meter No pulse output Is the connecting correct Maybe there is a fault in the...