1. Part / Part No. / Accessories
LUXOMAT
®
Thermostat
TRV2-ZW:
92046
For accessories, refer to
www.luxomat.com/en-92046
Scope of delivery (included in the box)
1 TRV2-ZW energy saving radiator thermostat
1 User manual
1 Connector
3 Adapters
Application as directed
With the TRV2-ZW energy-saving control, you have acquired a
wirelessly connected radiator control designed to control tem-
peratures in enclosed rooms and thus reduce heating energy
consumption.
Please use the thermostat only for this purpose.
The TRV2-ZW programming port is intended ONLY for our USB-
TRV2 (
Accessory:
92054
).
Never connect other devices with the
programming port!
2. Display and control elements
1
Heating times
2
Child lock
active
3
Battery
low
4.a
Travel function
active
4.b
Wireless connection
active
4.c
Comfort temperature
active
4.d
Economy temperature
active
4.e
Window/freeze protection
function active
5
AUTO or MANU mode active
6.a
Button
MENU
– leads to the main menu
(starting from regular display); within the
menu one keypress leads to the previous level
6.b
Button
OK
– confirmation of setting
6.c
Button
– timer function
7
Selector wheel
3. Set up menu
By pressing
MENU
you will arrive at the set up menu. Please
choose one of the items with the selector wheel. With
OK
you
can select one menu item and with the selection wheel they can
be adjusted. The button
OK
confirms the setting. The button
MENU
leads to the previous level.
to select the mode
AUTO = automatic mode
MANU = manual mode
PRAE = PRESENCE mode
APRA = Automatic mode + additional presence
detection
setting of time programme
setting of comfort and economy temperature
setting of date and time
window function
reset of the device to factory preset
starting of a new adaptation
to adjust the valve
travel function
installation function
adaptation of temperature to the room situation
4. Inserting / replacing batteries
Remove the battery cover where indicated using a screwdriver
and pulling the cover off.
Then insert the batteries as shown in the illustration.
f
Do not use rechargeable batteries! Ensure that the
polarity is correct!
Attention:
•
Never recharge batteries, danger of explosion!
•
Do not short-circuit batteries!
•
Do not disassemble batteries!
•
Take low batteries out of the device immediately.
•
Keep batteries away from extreme warming – danger of
leakage!
•
Do not apply used and new batteries together. If needed,
clean the battery and the contacts before using them.
•
Keep the batteries away from children.
•
When getting in touch with battery acid instantly irrigate the
affected parts with clear water and call a doctor.
5. Setting date and time
After inserting the batteries for the first time the date will flash
on the display. Now, date and time can be set.
Set date with the selector wheel. Confirm with
OK
.
Set month with the selector wheel. Confirm with
OK
.
Set day with the selector wheel. Confirm with
OK
.
Set hour with the selector wheel. Confirm with
OK
.
Set minute with the selector wheel. Confirm with
OK
–
That´s it.
On the display
will be shown. Now, the motor will com-
pletely move to the installation position in order to make the
installation easier. As soon as TRV2-ZW is ready for installation
will be shown on the display.
You can also set date and time via the menu item
later on.
But in case of that, TRV2-ZW does not move to the installation
position.
f
In case of replacing batteries, the stored time
programme will remain active. You should check the
specified time to ensure that.
6. Creating the wireless connection
1. Initialise the device before it logs in for the first time. The
menus may be navigated by using the adjusting wheel and
function keys. You can navigate to the menu item
with
MENU
f
f
OK
f
and confirming with
OK
2. The login procedure may now commence. To commence the
login procedure, switch the MyControl to learning mode:
f
f
The learning procedure for the TRV2-ZW is also started in
the next step.
MENU
f
f
OK
f
f
OK
A symbol representing the radiator control will be shown
in the MyControl display when the learning procedure has
been concluded.
3. Only the time for the repeater‘s cyclical query now needs
to be set. This time also automatically determines the
maximum period before the heating is switched on after
movement has been detected. The options are: 3, 4 or 5
minutes. You may navigate to these settings via
MENU
f
OK
f
f
Example
.....
f
OK
7. Installation
TRV2-ZW can be quickly and easily mounted on all common
valves (see adapter table). It can be installed without grime
and water spots because the heating circuit is not interrupted.
1. Turn the manual thermostat head up completely, loosen the
fastening and pull the thermostat off of the valve.
2. Use an appropriate adapter, if required, and push it onto
the valve.
3. Screw the connector on the valve or the adapter.
4. Now, you put TRV2-ZW on the connector until it noticeably
clicks into place.
f
In case of a
later installation
please switch in the
menu to
before
you install the device. Herewith the
installation is facilitated.
8. Dismounting
f
In order to dismount TRV2-ZW press the releasing
device to loosen the locking device. Now, pull the TRV2-
ZW off of the valve.
9. Adaptation
Initial installation: Press the button
OK
until
appears on
the display so that TRV2-ZW will be able to start its adaptation.
The device will adapt itself to the stroke of your valve body. To
do this the valve will now be opened and closed several times
to store the end points.
In some cases this process can take a few minutes. After success-
ful adaptation it returns to normal mode.
f
Should adaptation become necessary again, e.g. if
your radiator does not cool down in the
position,
please press in the menu the button
until adapta-
tion starts again.
f
If the mistake is shown on the display place TRV2-ZW
onto the radiator valve and then take the batteries out for
a short time in order to execute a reset.
10. Basic operating modes
MANU-mode
In the MANU-mode TRV2-ZW adjusts to the manually specified
temperature.
AUTO-mode
In AUTO mode, he TRV2-ZW operates as a standalone unit
(without motion detection) and switches between two tempe-
ratures depending on the settings made in the timer program:
comfort temperature
(factory preset 21°C)
economy temperature
(factory preset 16°C)
PreSeNce MOde
In presence mode, the TRV2-ZW will switch the heater to the set
comfort temperature when it detects motion. Otherwise the tem-
perature will remain at the previously set economy temperature.
AUTO-PreSeNce MOde
Auto-presence mode combines automatic mode with presence
mode, i.e. fixed heating times may set during which the economy
control switches the heating to the specified comfort temperature.
When economy temperature is active, the unit will adjust the
heating depending on its presence-detection, i.e. it will activa-
te the heating if it senses any movement.
The heating and economy times can be specified via the ad
-
justable time programme. It is possible to set 8 switch points (4
heating and 4 economy times) per day at the most. TRV2-ZW
has the following factory preset:
B.E.G.
Installation and operating instructions for
B.E.G.
– programmable energy-saving radiator thermostat
LUXOMAT
®
TRV2-ZW
LUXOMAT
®
TRV2-ZW
GB
i
i
i
i
i
USB-TrV2
(Accessory optional)
TrV2-ZW
1
4
2
3
5
7
6