Installation and Operating Instruction for
B.E.G.
- Occupancy detector PD4-M-DALI/DSI-SM/FC
LUXOMAT
®
PD4-M-DALI/DSI / PD4-S
1. Product information
EN
3. Safety information
Work on the 230 V mains supply may only be
carried out by qualified professionals or by
instructed persons under the direction and super-
vision of qualified skilled electrical personnel in
accordance with electrotechnical regulations.
Disconnect supply before installing!
This device is not suitable for disconnection.
Mounting the cover ring, after introduction of the
power cable (FC version)
!
!
!
!
!
4a. Mounting SM
4b. Mounting FC
68 mm
5a.
Position DIP-Switches, LEDs and
Potentiometer SM
5b.
Position DIP-Switches, LEDs and
Potentiometer FC
LED I
green
LED II
red
LED III
white
The light sensor should be mounted on the opposite
side of the window.
In Master-/Slave-operation the master device must
always be installed at the site with less daylight.
A circular opening of diameter 68 mm must be produced in the
ceiling. Having connected up the cables in accor dance with
regulations, the detector is inserted into the opening as shown in
the drawing opposite and fixed into position with the assistance of
the spring clips.
2. Operation
The presence detector controls the light automatically according
to people present (movements) and the ambient brightness.
The integrated light sensor constantly measures the ambient light
and compares it with the brightness level on the detector. If the
ambient light is sufficient, lighting will not be switched..
If the ambient light level is below the brightness level, a move-
ment activated the lighting in the room.
The detector switch the light off instead of a person, if there is
enough natural light for 5 min. or until the follow-up time do not
recognized any movement in the room.
•
Occupancy sensor for daylight-dependent lighting control
•
DALI / DSI interface for controlling digitally dimmable
electronic ballasts as a group
•
Switching between DSI and DALI program by remote
control or DIP switches
•
Version as Master
•
Extension of the coverage area by slave devices are
possible
•
Other functions can be adjustable by remote control.
•
Manual switching and dimming via pushbutton
possible
•
Orientation light function
The detector must be mounted on a flatsolid ground. Before
mounting the detector, the lens must be removed. The circu-
lar cover ring must be removed prior to assembly. To do this,
twist the circular cover ring of the PD2 anticlockwise through
approximately 5° and lift off.
Having connected up the wires in accordance with
regulations, put on the cover ring by turning in a clockwise
direction. Apply mains voltage.
open
close
DIP-switch function
DIP 1
Fully automatic mode
(VA)
Semi automatic
mode (HA)
DIP 2
LED ON
LED OFF
DIP 3
operation mode DALI
operation mode DSI
Potentiometer A
Brightness constant light control
Potentiometer B
Off delay for light
Potentiometer C
Orientation lighting
!
The product enters an initial 60-second self-test cycle, when the
supply is first connected. During this time the device does not
respond to movement and stays on. (INI-ON or INI-OFF)
The initialization mode can be changed by using the remote control
6. Self test cycle/Startup behavior
7. Putting into operation / Settings
Follow-up time for light control
The time can be set infinitely variably between
1 and 30 minutes.
Symbol
TEST
: Test mode
Every movement switches on the light for a period of 1
second, switching it off for a period of 2 seconds.
Twilight-switch for light control (relay 1)
The switch-on value for the light can be set at between
10 and 2000 Lux. Using the rotary control, the luminan-
ce set points can be set as desired.
Symbol
: Night-time operation
Symbol
: Daytime operation
Orientation lighting
The orientation lighting can be set infinitely variably at
between 5 and 60 minutes resp. "ON" for permanent
orientation lighting or "OFF" for no orientation lighting.
"ON" for permanent orientation lighting
"OFF" deactiviation of orientation lighting.
Pulse spacing PD-Slave
2 or 9 seconds can be set for the pause between 2
pulses sent to the master. The setting can be made with
activated ( ) or deactivated ( ) LED indicator.
For devices with a separate Slave input, 2 sec.
can be set.
TIME
TE
1
3
6
22
18 16
10
30
25
LUX
40
2000
600
1200
200
20%
60
5
10
50 30
O
FF
O
N
9s
2s
LED ON
LED OFF
9s
2s
LED ON
LED OFF
TIME
TE
1
3
6
22
18 16
10
30
25
LUX
40
2000
600
1200
200
20%
60
5
10
50 30
O
FF
O
N
9s
2s
LED ON
LED OFF
TIME
TE
1
3
6
22
18 16
10
30
25
LUX
40
2000
600
1200
200
20%
60
5
10
50 30
O
FF
O
N
9s
2s
LED ON
LED OFF
8. Wiring diagram
Standard mode with Master/Slave
Master
Slave
L
N
E1 DALI/DSI
L
N
DA
DA
L
N
R
S
+
-
DALI
N L
R
T1
Master
Slave
L
N
E1 DALI/DSI
L
N
DA
DA
L
N
R
S
+
-
DALI
N L
R
T1
Connected Slaves must have the same phase
as the Master.
9. Manual switching and dimming
By pressing the push button, the phase can be given to the S
terminal.
To turn on or off, press the push button briefly. The light will
remain on or off, as people are detected plus the follow-up time.
With a long key press the light will dimmed manually. When
you release the button, the current brightness value is retained.
With renewed dimming, the dimming direction is reversed.
!
I
II III
PD4-
False ceiling
mounting
C
B
A
Light measu-
rement
C
B
A
PD4-
Surface
mounting
Light measurement
DIP
LED
OFF
DSI
DALI
VA
HA
LED
ON
1
I II III
2
3
DIP
DALI_D
SI
LED ON_ LED OFF
VA_HA
1
2
3
PD4-M-DALI-DSI-DE_270213.indd 1
27.03.2014 10:15:51