B.E.G. LUXOMAT PD3-1C Скачать руководство пользователя страница 1

4 m

Installation and Operating Instruction

2a.    Installation of the LUXOMAT

®

 PD3-1C-SM 

2b.    Installation of the LUXOMAT

®

 PD3-1C-FC 

Sensor and power supply in one case

Power supply:

 

230 V~ 

±

10 %

Power consumption:

 

< 1W

Ambient temperature:

 

-25°C to +50°C

Degree of protection /class:

 SM IP44, FC IP20 / II

Settings:    

locally

Area of coverage:

 

circular 360°

Range of coverage Ø H 2.50 m / T = 18°C:

 smaller movements 4 m / tangential 10 m / radial 6 m

Recommended height for mounting:

  

2 - 3 m

Light measurement:

  

 mixed light, da artificial 

light 

Lux values - Potentiometer:

 10 - 2000 Lux

• Channel 1 for light-connection

Type of contact:

 

 NOC/with pretravel tungsten 

contact

Contact load:

  

 2000 W, 230 V~, cos

ϕ

=1 /  

1000 VA cos

ϕ

= 0.5 

Time-settings:

 

30 sec. - 30 min. / Test

Dimensions H x Ø [mm]

 AP 

DE 

PD3-1C 

52 x 106 84.5 x 80 

Visible portion when built into ceiling:

 15 x 80 mm

Version: 

v.01

 

Declaration of Conformity: 

The product complies with 

the low voltage recommendation 2006/95/EC and the 

EMV recommendation 2004/108/EC.

4. Technical data PD3-1C

5. Trouble shooting

1. Lamp does not light up 

Lamp may be defect:

Replace lamps

No mains connection/power:

Check connection and mains fuse by qualified electrician

Incorrect setting of CDS twilight threshold:

Correct setting of CDS threshold

Lens of sensor unit obstructed by dirt or other objects:

Clean lens, remove objects

2.  Lamp turns ON too late or detection range too small

PD3-1C is mounted too high:

 

Correct mounting if required.

3. Lamp stays ON continuously

Continuous thermal activity detected ie fan, central heat-

ing ducts, animals within detection area:

Remove heatsource. Check proper function of PD3-1C by 

covering the fresnel-lens. After expiry of delay timer, 

PD3-1C has to turn OFF lighting.

PD3-1C

 connected in parallel to a manual override 

switch:

Connect switch correctly

4. Unintended switching of light

Movement of heat source within detection area:

Check on presence of animals, fans or heaters

The detector must be installed on a 

solid and level surface. There is no 

need for frames. 

For mounting remove lens (C) (turn 

anticlockwise). Fasten the mounting 

base to the ceiling.

Having connected up the wires in accordance with 

regulations, secure the detector with 2 screws as per the 

illustration above. 

 1. Mounting preparations

Work on the 230 V mains supply may only be carried out by quali-

fied professionals or by instructed persons under the direction and 

supervision of qualified skilled electrical personnel in accordance 

with electrotechnical regulations.

Disconnect supply before installing! 

The detector has been designed 

and developed specifically for 

installation in suspended ceilings. 

A circular opening of diameter 

68 mm must be cut into ceiling. 

Having connected up the cables in accor dance with 

regulations, the detector is inserted into the opening as 

shown in the drawing above and fixed into position with 

the assistance of the spring clips.

7. Article / Part nr.

6. Range of Coverage

quer zum Melder gehen 
frontal zum Melder gehen
Unterkriechschutz

Walking across
Walking towards
 Smaller  movements

1

2

 3. Putting into operation / Settings

Initialization  

In the first 60 seconds after connecting the power supply, the  

LUXOMAT

®

 PD3-1C goes through a self-check. During this time the 

detector does not react to the movements, but the detector stays on 

or off, depending on the choice of the initalization mode.

INI-OFF/ON 

You can adjust, whether the detector stays on or off 

during the first 60 seconds of the initialization  mode.

      

Attention: 

During INI-OFF the detector does not 

switch on, after adding the power supply. Even a 

movement brings the detector to switch on after 60 

seconds.

Follow-up time for light control

The time can be set infinitely variably at between 

30 seconds and 30 minutes. 
Symbol  : 

impulse < 1sec. 

 Symbol 

TEST

:   Test mode  

(Every movement switches on the light for a period of 

1 second, switching it off for a period of 2 seconds 

after that regardless of the level of brightness.)

Twilight-switch for light control

The switch-on value for the light can be set at 

between 10 and 2000 Lux. Using the rotary control, 

the luminance set points can be set as desired. 
Symbol  : 

Night-time operation

Symbol  :   Daytime/Night-time operation

Adjusting sensitivity

For sensitivity adjustment of the detector, both in 

the interior and the exterior range, the PD3-1C is 

equipped with an additional knob (see pictures) for 

excluding sources of interference, e.g. bad weather 

conditions or draught air.
Max: 

  for  interior  use   

(recognition of the slightest movements)

Min: 

 for exterior use  

(exclusion of sources of interference)

120 6050

40

30

15

10

A

16 10

5

2

1

30

15

TEST

2000

1200

600

200

40

5

max.

min.

2

4

6

8

12

30

secs

30

mins

1

min

TEST

2000

1200

600

200

40

10 m

6 m

4 m

10 m

360°

2.50 m

1

2

3

3

Type

SM

FC

PD3-1C

92194

92197

ca. 68 mm

INI- 

ON

INI- 

OFF

!

B.E.G.

LUXOMAT

®

 

PD3-1C

RUS

Отзывы: