Important

 – set flow meter to 1000 gallons 

 

 

 

-Filter placement above- 

 

                                                                                             (B. David Specific filters)  

    

 

 

 

Specifications

 

Pressure Range: 

Temperature Range:

 

Service Flow Rate

 

@60 psi (4

.

1 bar):

 

Rated Service Life:

 

   

   

   

2.1--8.62  bar (20-115  psi)

 

4.4-38.8°C (4G-102°F)

 

   

2.3 Lpm at 

4.1 

bar 0.6 gpm 

3,785 L (1000 gallons)

 

   

• 

After prolonged periods of non-use (such as during a vacation) it 
is  recommended  that  the  system  be  flushed  thoroughly.  Let 
water  run for 5-6 minutes before using.

 

• 

The filter 

cartridges 

used with this system have a limited service 

life. Changes in taste, odor, and/or flow of the water being filtered 
indicate that the cartridges should be replaced.

 

Dimensions: 

394 mm 

133 mm 

356 mm 

(15.5 in. 

5.25 in. 

14 in.)

 

Weight (filled with water):  8.6 kg (19 lbs.)

 

   

Parts Included

 

•Filter 

system with filter cartridges

 

•Installation 

hardware (mounting screws, saddle valve, fittings)

 

• 6.35 mm (1/4-inch) tubing

 

• 

Lead-free faucet

 

I       Installation

 

•  For standard under-sink installation on 10 mm (3/8-inchl cold 

water line.

 

•  Please read all instructions and precautions before installing and 

using 

your filtration

 System.

 

•  Numbered  diagrams  correspond 

with 

numbered 

steps.

 

   

1.

 

 Installing 

the Saddle Valve

 

Diagram on page 2

 

Use of a hand drill is recommended. To protect

 

Tools 

and  Materials 

Required:

 

• 

Safety Glasses

 

•Hand 

or 

electric  drill 

(cordless  recommended)

 

•File

 

• 

Phillips head screwdriver

 

•2 Adjustable wrenches

 

•Tube 

cutters or utility knife

 

   

   

Precautions

 

Iiiif sink does not have hole 

for separate faucet:

 

• Center punch

 

• 19 mm (3/4-inch) drill bit

 

yourself from serious injury or fatal shock when using an electric drill, 
be sure the drill and 

the 

outlet it is plugged into are properly 

grounded. When using a drill, follow the manufacturer's guidelines 
and procedures.

 

NOTE: Saddle valve must be installed on a 51 mm (2-inch) long, straight

-

walled 

section 

of 10-22 mm (3/8-inch to 7/8-inch) 

steel, 

brass,  copper, or 

PVC pipe.

 

(A)  Turn off  cold water supply and (turn on nearest 

faucet 

before 

starting 

installation. Place 

tray or towels under the 

cold 

water 

line to catch  excess water

.

 

(C)  Drill a 3  mm  (1/8-inch)  hole in  cold water  line

Remove  any 

burrs with sandpaper or file

.

 

(D)  Turn handle on the 

saddle 

valve to expose lance no more than 5

 

 

WAR NING

   

L

Protect filters against freezing, which can cause 

cracking of the filter and water leakage.

 

The rubber o-ring provides the water-tight seal between 

the cap and the bottom of the housing. It is important that 
the 

o-ring

 

be properly seated in the groove below 

the 

threads of the 

housing or a  water leak could occur

.

 

To prevent costly repairs or possible 

water 

damage, the 

sump of plastic housings must be replaced every five years 
for clear, 

and 

ten years for opaque. If sump is older than 

recommended, replace immediately. Date 

sump 

for 

reference and 

indicate replacement 

date.

 

NOTE:

 

• 

For cold water use only.

 

• 

Make certain that installation complies 

with 

all local 

laws and regulations.

 

mm (3/16-inch) beyond black rubber gasket.

 

(E)  Place valve body over hole in cold 

water 

line 

so 

lance fits 

into 

hole.

 

(F)  Attach  back plate of clamp  and tighten bolts evenly and firmly so 

brackets are  parallel.

 

(G)  Turn valve 

handle 

clockwise to closed position and leave closed 

until installation is complete.

 

2. 

Selecting the Faucet Location

 

Diagram on page 

2

 

NOTE: The drinking water faucet should be positioned with function, 
convenience, and appearance in mind. An adequate flat area is 
required to 

allow faucet 

base to rest securely. The faucet fits 

through a 

19mm 

(3/4-inch) hole. 

Most sinks 

have pre

-

drilled 35 or 

38mm

 

(1-inch

diameter holes that may be used for faucet  installation of 

these pre-drilled holes cannot be used or 

are 

in 

an 

inconvenient 

location, it will be necessary to drill a 19mm (3/4-inch) hole in the 
sink to accommodate 

the 

faucet. 

 

   

Содержание 9333

Страница 1: ...r s guidelines and procedures NOTE Saddlevalvemustbeinstalled on a 51mm 2 inch long straight walled section of 10 22mm 3 8 inchto 7 8 inch steel brass copper or PVC pipe A Turn off cold water supply and turn on nearest faucet before starting installation Place a tray or towels under the cold water lineto catch excess water C Drill a 3 mm 1 8 inch hole in cold water line Remove any burrs with sandp...

Страница 2: ... system over screws on wall and slide sideways Tighten screws Caution Make certainsystem isfirmly attachedto wall to preventitfrom falling and possibly being damaged 5 Connecting the Faucet diagrams on page 3 Caution Do not over tighten compression nut Use caution not to bend or crimp tubes when securing A Locate compression nuts ininstallation kitand faucet package 8 Attach compression nuts to fa...

Страница 3: ...ment Filter cartridges will last about 3785 liters 1 000 gallons or twelve months before they need to be replaced Filter cartridge life varies depending on filter life usage and or water conditions Changes in taste color and flow of the water being filtered indicate that the cartridge should be replaced Read all instructions before replacingfilter cartridges 1 Turn off cold water supply to system ...

Страница 4: ...eriodfor quickchangeheadsshallbe a periodoftwo 2 years Any replacementproductsfurnished willbefreefromdefectsinmaterialand orworkmanship forthe remainder oftheoriginalwarranty periodor 30days whichever is longer This warrantydoesnotcover 1 cartridges filterbags media UVbulbs andaccessories 2 defectsnotreportedwithintheabovetimeperiod 3 itemsmanufactured byothercom panies 4 problemsarisingfromfailu...

Отзывы: