B.David Company 4000Nanotechnology Скачать руководство пользователя страница 8

Troubleshooting the System 

Problem:    

Leaks between cap and bottom of filter housing 

Correction: 

Turn off water supply and turn on drinking water faucet to release pressure in 
system.  Remove bottom of housing.  Clean O-ring groove (located directly 
beneath threads of housing). Lubricate O-ring with silicone grease and replace 
securely into groove.  Screw bottom of housing onto cap and hand-tighten.  DO 

NOT OVER-TIGHTEN.  Turn on water supply and check for leaks 

Problem:  

Leaks on system inlet/outlet connections 

Correction: 

Turn off water supply and turn on drinking water faucet to release pressure in 
system.  Remove tubing from fitting and make sure end of tubing is cut squarely 
and free of burrs.  Reinsert tubing into fitting, making sure to push tubing to a 

hard stop.  Hand-tighten compression nut first, then tighten 1 to 1 1/2 turns for 
new compression nut.  Tighten only 1/2 to 1 turn with wrench for previously 
tightened compression nut.  

NOTE:  If leaks persist, or if there are other leaks in system, turn off water supply. 

Problem: 

Leaks on faucet / tubing connection 

Correction: 

Turn off water supply and turn on drinking water faucet to release pressure in 
system.  Loosen and remove compression nut fitting on faucet stem. Make sure 

tubing is inserted firmly into end of faucet stem, then retighten compression nut 
with fingers until secure.  Turn on saddle valve, and then turn off faucet to check 
for leaks.        

NOTE:  If leaks persist, or if there are other leaks in system, turn off water supply. 

Problem: 

No water or decreased water flow. 

Correction: 

Check flow at faucet. The 4000 Nanotechnology Certified Under Counter 
Filtration System

 

system should fill a gallon jug in approximately 2 minutes.  Flow 

rates will vary with individual household water pressure. 

Correction: 

Check filter cartridge installation.  Make certain all filter cartridges are properly 
oriented in filter housings. 

Correction: 

Replace filter cartridges. 

Parts List 

ITEM# 

QTY 

PART# 

DESCRIPTION 

ITEM# 

QTY 

PART# 

DESCRIPTION 

4002991 

MTG BRACKET, 3 HOUSING WHITE 

15 

4003 

THIRD STAGE DE BLOCK 

144169-02 

MTG BRACKET, 3 HOUSING WHITE 
(ALTERNATIVE) 

16 

4002 

 SECOND STAGE FI FILTER 

SH244788 

ELBOW, 1/4" NPT X 1/4" QC WH PP 

17 

4001 

 FIRST STAGE NANO FILTER 

SH244791 

NIPPLE, MALE HEX 1/4" NPT X 1/4" NPT 

20 

161123 

FILTER TIMER MONITOR, 12 MONTH 

158125 

1/4" #10 SL WHITE WO/PR 12/C 

21 

161125 

INSTRUCTION SHEET, TIME STRIP 

SH143263 

SCREW #6X 1/4" LG PHIL PAN 

22 

0.0240 

RL 

SH144223 

MACHINE TAPE, TEFLON 1/4" WIDE 

42561 

LUBRICANT, SILICONE, PACKET 

25 

1611161 

MANUAL, B. DAVID COMPANY 4000 
NANOTECHNOLOGY CERTIFIED UNDER COUNTER 

FILTRATION SYSTEM 

150539 

WRENCH SW-1A 

26 

10.000 

FT 

SH243244 

TUBE, 1/4" OD WHITE PE 

12 

PW-80-09 

SCREW, #10 - 32 X 3/4" PAN HEAD 

27 

161143 

DM FITTING; 1/4" X 1/4" QC; NPT 

4002987 

VALVE, SADDLE 1/4 COMPRESSION 

24 

N/A 

10 

SH243249 

SCREW #10-12 X 1.5 TYPE A 

32 

0.1250 

FT 

SH243244 

TUBE, 1/4" OD WHITE PE 

11 

C143026 

LOCAL "O-RING" 

33 

0.4583 

FT 

SH243244 

TUBE, 1/4" OD WHITE PE 

13 

244960 

DEFENG FAUCET, STANDARD 

34 

244985 

INLINE FLOW RESTRICTOR, 0.5 GPM 

14 

161127 

METER, 1800 GALLON, 1/4 NPT 

Содержание 4000Nanotechnology

Страница 1: ...South Bloomington MN 55431 952 884 8417 Info bdavidwater com www bdavidwater com Installation and Operation Manual System tested and certified to meet the requirements of NSF Protocol P231 and NSF ANS...

Страница 2: ...efective product or part B David Company will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by B David Company with an RGA number 2 inc...

Страница 3: ...f water that is visually contaminated cloudy or has an obvious contamination source such as contamination by raw sewage v Systems certified for cyst reduction may be used on disinfected waters that ma...

Страница 4: ...nch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious injury or fatal sho...

Страница 5: ...nd person hold the faucet while tightening the wing nut d Install the faucet spout into the base by pushing firmly into hole in base then screw fitting cover hand tight Caution Do not over tighten the...

Страница 6: ...Setting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5 L a Move...

Страница 7: ...d caps with dish soap and warm water Rinse thoroughly Then fillbottom ofeach housing1 3 full with water Add 1TBSP 14 7ML of household bleach and scrub to disinfect 5 Lubricate O rings with clean silic...

Страница 8: ...are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet The 4000 Nanotechnology Certified Under Counter Filtration System system shoul...

Страница 9: ...EXPLODED PARTS VIEW...

Страница 10: ......

Страница 11: ......

Отзывы: