                                                                                                                                                                           Page 

What the Microbiological Drinking Water Purifier Will Do . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 
Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 
Specifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 
Parts of the System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Materials & Tools Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 
 

Step 1 – Installing the Saddle Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4 

 

Step 2 – Selecting the Faucet Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 

 

Step 3 – Mounting the Faucet . . . . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 

 

Step 4 – Mounting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 

 

Step 5 – Connecting the Faucet . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 

                Step 6 – Attaching Tube . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 
 

Step 7 - Connecting the Saddle Valve . . . . . . . . . . . . . .  . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 

 

Step 8 – Connecting the Inlet Line to System  . . . . . . . .  . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 

 

Step 9 – Setting the Effective Life Indicator . . . . . . . . . .  . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   6 

 

Step 10 – Putting the System into Operation  . . . . . . . . .  . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 

Filter Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 
Filter Cartridge Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7 
 

Filter Cartridge Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7 

Troubleshooting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8 
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . .  9 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY 

ONE YEAR LIMITED WARRANTY ON MICROBIOLOGICAL DRINKING WATER PURIFIER 

Warrantor:  B. David Company,  9333 Sheridan Ave. S., Bloomington, MN 55431 

B. David Company warrants to the original owner (under normal use): all products and parts to be free from defects in material and workmanship for a period of one (1) year from the 
date of purchase.  Any replacement products furnished will be free from defects in material and/or workmanship for the remainder of the original warranty period or 30 days, 
whichever is longer.  This warranty does not cover: (1) defects not reported within the above time period, (2) problems arising from failure to comply with B. David Company 
instructions, (3) problems and/or damage arising from acts of nature, abuse, misuse, negligence or accident by any party other than B. David Company, (4) problems and/or damage 
resulting in whole or in part from alteration, modification, repair or attempted alteration, modification or repair by any party other than B. David Company, (5) noncompliance with 
applicable codes/ordinances. 
 
If a defect in workmanship and/or material in a product or part covered by the warranty should arise

B. David Company,

 

at its sole discretion, will repair or replace the defective 

product or part (B. David Company will consider the customer’s preference in good faith). 
 
All claimed defective product must: (1) be authorized for return by B. David Company with an RGA number (2) include proof of the purchase date of the product or part (3) returned 
to B. David Company prior to the expiration of the warranty date at the customer’s expense, shipment pre-paid (4) be accompanied by a letter detailing the Model Number, Serial 
Number (if any), and a brief description of the problem. 
 
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, B. DAVID COMPANY DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT 
LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCTS, PARTS AND ANY ACCOMPANYING 
WRITTEN MATERIALS. 
 
To the maximum extent permitted by applicable law, B. David Company shall not be liable for any damages whatsoever (including, but not limited to, loss of time, inconvenience, 
expenses, labor or material charges incurred in connection with the removal or replacement of the products or parts, special, incidental, consequential, or indirect damages for 
personal injury, loss of business profits, business interruption, loss of business information, or any other pecuniary loss) arising out of the use of or inability to use the defective 
products or parts even if B. David Company has been advised of the possibility of such damages. 
 
The B. David Company maximum liability under any provision of this Limited Warranty shall be limited to the amount actually paid for the products or parts. 
 
This warranty is effective if the Microbiological Drinking Water Purifier is operated at water pressured between 30-100 psig and a water temperature between 40-100°F.  
Furthermore, the purifier must not be subject to mistreatment, system modification, disregard, freezing, carelessness, or damage as a result of any unusual force of nature (i.e. 
hurricane, flood, earthquake, or tornado).  Warrantor is excused if failure to perform its warranty obligations is the result of material shortages, government regulation, strikes, or any 
other circumstances beyond its control. 

 

 
 

Содержание 4000Nanotechnology

Страница 1: ...South Bloomington MN 55431 952 884 8417 Info bdavidwater com www bdavidwater com Installation and Operation Manual System tested and certified to meet the requirements of NSF Protocol P231 and NSF ANS...

Страница 2: ...efective product or part B David Company will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by B David Company with an RGA number 2 inc...

Страница 3: ...f water that is visually contaminated cloudy or has an obvious contamination source such as contamination by raw sewage v Systems certified for cyst reduction may be used on disinfected waters that ma...

Страница 4: ...nch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious injury or fatal sho...

Страница 5: ...nd person hold the faucet while tightening the wing nut d Install the faucet spout into the base by pushing firmly into hole in base then screw fitting cover hand tight Caution Do not over tighten the...

Страница 6: ...Setting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5 L a Move...

Страница 7: ...d caps with dish soap and warm water Rinse thoroughly Then fillbottom ofeach housing1 3 full with water Add 1TBSP 14 7ML of household bleach and scrub to disinfect 5 Lubricate O rings with clean silic...

Страница 8: ...are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet The 4000 Nanotechnology Certified Under Counter Filtration System system shoul...

Страница 9: ...EXPLODED PARTS VIEW...

Страница 10: ......

Страница 11: ......

Отзывы: