Instructions for use/Technical description

DSM (Digital Surgical Microscope)

Содержание Aesculap DSM

Страница 1: ...Aesculap Aesculap Power Systems USA Instructions for use Technical description DSM Digital Surgical Microscope ...

Страница 2: ......

Страница 3: ...1 3 4 5 6 2 ...

Страница 4: ...port 9 5 2 System set up 9 5 2 1 3D display and robotic arm workspace 9 5 2 2 Connecting the accessories 10 5 2 3 Connecting the power supply 10 5 3 Function checks 10 5 4 Positioning the 3D display 10 5 5 Turning the system on 11 5 6 Setting up the robotic arm and the DSM head 11 5 6 1 Rotating the DSM using the yaw coupler 11 5 6 2 Moving the robotic arm out of storage position and draping the r...

Страница 5: ... this device Symbol Location Description Base of cart Main power switch Press to turn the system ON Press again to turn the system OFF Product label AC input DSM head DC input Product label Warning Product label Risk of electric shock Do not open Robotic arm Take care to avoid injury when in the vicinity of the display arm or robotic arm Support arms Do not exceed load ratings for support arms Pro...

Страница 6: ...head with the lens cap covering the main objective when it is not in use Do not cover the air vents of the system touchscreen or 3D display Note When the emergency stop is pressed the DSM head may move up to 3 cm depending on position due to mechanical brakes locking into place This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of th...

Страница 7: ...t if the inclination passes 35 Only use footswitch on a firm even horizontal surface When using the backup cable When connecting the backup cable always ensure that connecting ele ments plugs are clean Ensure that the plug connections are not subjected to mechanical loads Do not subject backup cable to excessive pulling pressure or bending Do not drive over cable Always perform function test in co...

Страница 8: ...playback due to real time compression of the video stream as it is recorded The compressed video files can easily be transferred to exter nal storage for backup and archival and to free space on the internal stor age drive The cart also holds a second computer controlling the robotic arm 3 3 1 Emergency stop The robotic arm emergency stop is located at the top of the cart The robotic arm movement ...

Страница 9: ...cord connection i the DSM system is equipped with a 6 mm potential equalization port j that can be connected to the healthcare facility potential equalization system Connect the display to the potential equalization port j at the front of the cart see Fig 5 Connecting to a PACS RIS server There are two Ethernet ports on the both the front and back panels of the cart Ensure that the Ethernet cable ...

Страница 10: ...attery connect the keyboard to a USB port a on the side of the touchscreen mount using the Micro USB cable supplied see Fig 5 The battery indicator blinks green while charging Charge until the indicator light stops blinking Note The keyboard can be used while it charges Note If the battery power is low indicator blinking red the keyboard backlight is disabled 3 10 Polarized 3D glasses Passively ci...

Страница 11: ...cially over elevator and door thresholds 5 2 System set up 5 2 1 3D display and robotic arm workspace To help with positioning the DSM in the operating room the cart dimen sions the minimum and maximum extensions of the 3D display arm and the height and maximum extension of the robotic arm are shown below Fig 8 Legend a Max length arm fully extended b Max monitor height c Min monitor height d High...

Страница 12: ...rection Connect the main power cable see Chapter 5 2 3 Connect any external input or output video or Ethernet cables see Chapter 3 3 3 Check that there are no unnecessary objects or people within the range of the robotic arm workspace Check that the DSM head optical path is clean and free from dust Ensure that exposed cables for the footswitch any external displays and power supply are laid flat o...

Страница 13: ... 22 Under Coupler press the Reconfigure Coupler button Press and hold the Hold or Reconfigure position button until the arm is fully extended Fig 13 Legend a Sliders of the yaw coupler Unlock the sliders a and rotate the DSM manually into the desired posi tion The available coupler positions are illustrated below The geometry lim its of the robotic arm will change based on the coupler position Fig...

Страница 14: ... DICOM server if applicable local drives or connected external drives 5 9 Saving case media If snapshots and or images were recorded ending the current case will prompt users to save the media The patient information can also be updated at this time even if the case was started with previously saved information 5 9 1 Save to default location After selecting to end the case Fig 16 Press Yes to cont...

Страница 15: ...ically provide further options to Shut Down or press Can cel button return to the application Fig 20 5 12 Changing footswitch batteries Battery type 3 IEC LR14 Type C Baby Shut down DSM see Chapter 5 11 Open battery housing Rotate both lockers near battery housing by 90 While doing so lightly press down the battery cover Lift the empty batteries by the ejector belt and remove them Insert new batte...

Страница 16: ...joint limits If this occurs move the robotic arm to a preset position Note If proper rebalancing of the DSM stillresults in unsatisfactory balance con tact Aesculap Technical Service for assistance see Chapter 10 6 2 3 Robot recovery If communication is lost with the force torque sensor or the coupler and the robotic arm becomes difficult or impossible to move the arm joints need to be manually re...

Страница 17: ... light level Activate the fluorescence function by selecting the DUV 400 On but ton on the touchscreen or the corresponding handle or footswitch but ton The DSM Control panel will still be available and additionally the DUV Light Level value bar can be adjusted while DUV 400 is on Select Overlay to show an overlay of captured fluorescence in the live view Select FL Off to turn off near ultraviolet...

Страница 18: ...zing Ready State Displayed when arm is ready for movement Emergency Stop State Displayed when Emergency Stop button is engaged Protective Stop State Displayed when the robot is in a pro tective stop state after the arm movement is interrupted Soft Stop State Displayed when soft stop state is selected Footswitch Directional Move with No Restric tions Displayed when moving the arm with the footswitc...

Страница 19: ...o select or slide the value anywhere between 0 05 smallest diameter and 1 00 largest diameter The default Diameter is 0 75 Opacity Use the Opacity bar to select or slide the value anywhere between 0 05 most transparent mask and 1 00 most opaque mask The default Opacity is 0 50 6 8 4 DUV 400 Fluorescence In the DUV 400 panel the following settings for the DUV 400 s overlay can be modified Hue can b...

Страница 20: ...m any value between 1 and 10 to change the quality for recordings default 5 Squeezed SxS side by side checking the checkbox reduces resolu tion of saved media to 1920 1080 default unchecked Select this option when smaller file sizes and or the ability to edit with 3rd party editing software are required DICOM Record 3D when a DICOM patient is selected at the start of a case all media recordings wi...

Страница 21: ...ction using the Windows Control Panel 6 8 10 Handles In the Handles panel the layout and functions of the DSM head handles using can be customized Press the Left Right toggle to switch between handles See below for a list and description of each button s function Dual Mode Press the Dual Mode checkbox to enable disable this function When Dual mode is enabled both handles share the same configura t...

Страница 22: ...ata saved in a language other than the current language will not be displayed User manual Press User Manual to open the user manual folder found on the desk top Double click on the DSM user manual to open the PDF version Note The DSM application does not need to be closed in order to view the user manual More Press More to open a separate panel with two pages Page 1 contains system information inc...

Страница 23: ...s on each of the four casters and move the 3D display into the position illustrated above Twist the arm joint handles to lock the arm in place Lock the cart castors after moving the system 8 Maintenance Preventive maintenance The Digital Surgical Microscope does not consist of any device that requires a regularly maintenance within a defined time frame However in an interval of 12 month a regular ...

Страница 24: ...spots remain the dust may be inside the DSM head Contact Aesculap Technical Service see Chapter 10 Robotic arm not working Reboot the system or follow the error messages shown on the display Touchscreen not working Re connect the touchscreen Error message Remedy Already initialized Restart the system If that does not help contact the local Aesculap representative or Aesculap Technical Service see ...

Страница 25: ...s not accept able Check DSM head cable connections Contact Aesculap Technical Service see Chapter 10 WARNING Risk of death for patient and operator due to mal function and or failure of safety measures Do not perform any service or maintenance while using the product on the patient Do not modify the product CAUTION Modifications carried out on medical technical equipment may result in loss of guar...

Страница 26: ...Aesculap AG Am Aesculap Platz 78532 Tuttlingen Germany Phone 49 0 7461 95 0 Fax 49 0 7461 95 26 00 www aesculap com Aesculap a B Braun brand SOP AIC 5001887 TA015615 2019 02 ...