OPERATION MANUAL

Technical changes reserved
0141 0316-112   20.04.2016

Level controller for conducting liquits

WLS-GEH230V

Description

Description

Technical Data

General

Operating voltage

230 VAC / 5 VA max.

Relay

NO/NC contact for resistive load
Rating NO contact 230 V AC / 5 A
Rating NC contact 230 V AC /2 A

Surge suppression

NC contact with Varistor VZ 05 / 390 V

Dimensions

100 x 100 x 60 mm Supplied in plastic housing

CE-conformance

2014/30/EU

EMV-noise emission

EN 61000-6-3:2011

EMV-noise withstanding

EN 61000-6-1:2007

Sensor side

Switching point impedance

15-80 kΩ, adjustable over a potentiometer

Measuring voltage

max. 5 VSS

Measuring current

< 250 µA

Sensor with connection lead

High grade threaded electrodes

NIVFUE-ESCHR

Printed circuit board level probe

NIVFUE-GEDR

Our sensor catalogue is constantly updated. Sensors for special applications are available on request !

Features

• 

Level controller for conducting liquids

•  Simultaneous monitoring of 4 levels
• 

Two independent circuits for fill/empty

• 

Indication of fill condition and operating status through 8    

LED

•  Two high rating potential free relays with NO/NC contacts
•  Operating voltage depending on model: 230 V AC

1 / 11

Содержание WLS-GEH230V

Страница 1: ...noise withstanding EN 61000 6 1 2007 Sensor side Switching point impedance 15 80 k adjustable over a potentiometer Measuring voltage max 5 VSS Measuring current 250 A Sensor with connection lead High...

Страница 2: ...cription 5 2 4 Scope of supply 6 3 Assembly adjustment and configuration 6 3 1 Electrical connection 6 3 1 1 Safety instructions 6 3 1 2 Lines to the sensor set up 6 3 1 3 Operating voltage 7 3 1 4 Lo...

Страница 3: ...of trip current rating tripping characteristics and mecha nical fitment dimensions Bypassing protections lead to a considerable safety risk and hence is not allowed under any circumstances The connect...

Страница 4: ...red switching point A fifth electrode is placed at the bottom of the reservoir not shown in sketch which works as the reference electrode According to water contact the fill level is indicated through...

Страница 5: ...rection Relay 1 remains closed even after water contact with Electrode E1 9 Only if Electrode E2 again comes under water contact Relay 1 is switched OFF 10 Hence the lower level also has a provision o...

Страница 6: ...only after switching off the voltage The device should be mounted only at dry locations Due to wrong tightening of screws of the connection terminals or by use of inappropriate tool the terminals can...

Страница 7: ...ug connector as per pin configuration The device can be operated only with 230V AC supply The mains supply connection is protected against over voltage through a 390V varistor The safety of the device...

Страница 8: ...ensitivity After any change in cable length of the connection lines the adjustment should be checked again 3 3 Light emitting diodes LEDs The device status is indicated by a set of 8 LEDs which are pl...

Страница 9: ...c components can get damaged due to electrostatic discharge process ESD protection measures should be duly observed 3 5 1 Pin configuration of input socket RJ12 Pin Function Colour 6 core cable Discri...

Страница 10: ...nance free For applications in condensate tubs and for low liquid levels the sensing system can be constructed as a PCB which is mounted on the tank wall Such sensing elements should also be periodica...

Страница 11: ...0316 112 20 04 2016 Level controller for conducting liquits WLS GEH230V Attention Please avoid extreme mechanical and inappropriate exposure The device product is not suitable for potential explosive...

Отзывы: