4. CONFIGURATION
Item
Description
IP Address
IP address
Period
Period of sending statistical information (in minutes)
Table 50: SNMP configuration (R-SeeNet)
Every monitor value is uniquely identified by the help of number identifier
OID – Object
Identifier
. For binary input and output the following range of OID is used:
OID
Description
.1.3.6.1.4.1.30140.2.3.1.0
Binary input BIN0 (values 0,1)
.1.3.6.1.4.1.30140.2.3.2.0
Binary output OUT0 (values 0,1)
.1.3.6.1.4.1.30140.2.3.3.0
Binary input BIN1 (values 0,1)
Table 51: Object identifier for binary input and output
All SPECTRE v3 routers also provide information about internal temperature of the device
(OID 1.3.6.1.4.1.30140.3.3) and power voltage (OID 1.3.6.1.4.1.30140.3.4).
It is important to set the IP address of the SNMP agent (router) in field
Remote SNMP
agent
. After enter the IP address is in a MIB tree part is possible show object identifier.
The path to objects is:
iso
→
org
→
dod
→
internet
→
private
→
enterprises
→
conel
→
protocols
The path to information about router is:
iso
→
org
→
dod
→
internet
→
mgmt
→
mib-2
→
system
The list of available and supported OIDs and other details can be found in the application
note
SNMP Object Identifier
66
Содержание V3
Страница 1: ...Configuration Manual for v3 Routers ...
Страница 17: ...3 STATUS Figure 2 Mobile WAN status 8 ...
Страница 20: ...3 STATUS Figure 4 WiFi Scan 11 ...
Страница 29: ...4 CONFIGURATION Figure 11 Example 1 Topology of LAN Configuration Figure 12 Example 1 LAN Configuration 20 ...
Страница 37: ...4 CONFIGURATION Figure 17 Mobile WAN configuration 28 ...
Страница 64: ...4 CONFIGURATION Figure 36 IPsec tunnels configuration 55 ...
Страница 76: ...4 CONFIGURATION Figure 47 Example of the MIB browser Figure 48 Example of SNMP configuration 67 ...
Страница 91: ...4 CONFIGURATION Figure 59 Example 2 USB port configuration 82 ...