![B+B SmartWorx SE400 Series Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/b-b-smartworx/se400-series/se400-series_user-manual_460674058.webp)
45
SE400 SERIES
LACP Priority Settings
The LACP Priority Settings page allows you to configure the system priority for LACP.
To access this page, click
L2 Switching
>
Link Aggregation
>
LACP Priority Settings
.
Figure 50: L2 Switching > Link Aggregation > LACP Priority Settings
The following table describes the items in the previous figure.
The ensuing table for
LACP Information
settings are informational only: System Priority.
LACP Port Settings
Link Aggregation Control Protocol (LACP) provides a method to control the bundling of sev-
eral physical ports together to form a single logical channel. By configuring the LACP function,
the switch can negotiate an automatic bundling of links by sending LACP packets to the peer
device (also implementing LACP).
To access this page, click
L2 Switching
>
Link Aggregation
>
LACP Port Settings
.
Figure 51: L2 Switching > Link Aggregation > LACP Port Settings
The following table describes the items in the previous figure.
Table 33: L2 Switching > Link Aggregation > LACP Priority Settings
Item
Description
System Priority
Enter the value (1-65535) to designate the LACP system priority.
Apply
Click
Apply
to save the values and update the screen.
Table 34: L2 Switching > Link Aggregation > LACP Port Settings
Item
Description
Port Select
Select a port for the LACP Port Settings. The listed available settings are:
Port1-10.
However, the available settings are dependent on the connected LACP
device and may not be listed as displayed in the current figure.
Priority
Enter a variable (1 to 65535) to assign a priority to the defined port selection.
Timeout
Click the radio button to select a long or short timeout period.
Mode
Click the radio button to select the setting mode: Active or Passive.
Active: Enables LACP unconditionally.
Passive: Enables LACP only when an LACP device is detected
(default state).
Apply
Click
Apply
to save the values and update the screen.