91
SE400 SERIES
Diagnostics
Through the Diagnostics function configuration of settings for the switch diagnostics is avail-
able.
The Cable Diagnostics page allows you to select the port for applying a copper test.
To access this page, click
Diagnostics
>
Cable Diagnostics
.
Figure 109: Diagnostics > Cable Diagnostics
The following table describes the items in the previous figure.
The ensuing table for
Test Result
settings are informational only: Port, Channel A, Cable
Length A, Channel B, Cable Length B, Channel C, Cable Length C, Channel D and Cable
Length D.
Cable Diagnostics
Table 91: Diagnostics > Cable Diagnostics
Item
Description
Port
Click the drop-down menu to select a pre-defined port for diagnostic testing.
Giga ports are displayed with a channel A to D designation.
Copper Test
Click
Copper Test
to display the test result for the selected port.