QUICK START
GUIDE
Document Number:
EIS2-EXTEND-A_QSG_1417
CAT 3 phone wire-grade cabling
CAT 5 or higher Ethernet cabling
Recommended Equipment
Troubleshooting
Included
Accessories
DIN rail mount
Panel Mount
RJ-45 to RJ-11 cable
Removable Terminal Block
External AC to DC Adapter
EIS2-EXTEND-A
RJ-45 to RJ-11 cables
Removable Terminal Block
External Power Supply AC to DC
EIS2-EXTEND-A
Compact VDSL2 EXTENDERS
Before you begin
--
be sure you have the following:
If there is a condition where data is not
passing the first step is to check the link
LEDs.
Next, make sure that one device is
set to Master and the other to
Remote.
Make sure the setting for duplex is the
same on both the Master and Remote.
Since line noise may be contributing data
transmission interference, check on what
VDSL2 Profile is being used, as you may
have to test the devices under
Symmetrical data rates before returning
to Asymmetrical data rates.
The cable connecting the devices may
be degraded; perform tests with new
cables in a bench test environment.