QUICK START

GUIDE

Document Number: 

EIS2-EXTEND-A_QSG_1417

CAT 3 phone wire-grade cabling

 

CAT 5 or higher Ethernet cabling

Recommended Equipment

 

Troubleshooting

Included 

Accessories

DIN rail mount

Panel Mount

RJ-45 to RJ-11 cable

Removable Terminal Block

External AC to DC Adapter

EIS2-EXTEND-A

RJ-45 to RJ-11 cables

 

Removable Terminal Block

 

External Power Supply AC to DC

EIS2-EXTEND-A

  

Compact VDSL2 EXTENDERS 

Before you begin

--

be sure you have the following:

If there is a condition where data is not 

passing the first step is to check the link 

LEDs.

Next, make sure that one device is 

set to Master and the other to 

Remote.

Make sure the setting for duplex is the 

same on both the Master and Remote. 

Since line noise may be contributing data 

transmission interference, check on what 

VDSL2 Profile is being used, as you may 

have to test the devices under 

Symmetrical data rates before returning 

to Asymmetrical data rates.

 The cable connecting the devices may 

be degraded; perform tests with new 

cables in a bench test environment.