Azonix Barracuda 15

DRAFT - 16 September 2014

Azonix Barracuda 15”

Rugged Zone 2 Workstation

September 2014
INM 19-102156 A

Instruction Manual

HMI and Visualisation

Содержание Barracuda 15"

Страница 1: ...DRAFT 16 September 2014 Azonix Barracuda 15 Rugged Zone 2 Workstation September 2014 INM 19 102156 A Instruction Manual HMI and Visualisation...

Страница 2: ...nd does not convey any license under the patent rights of Azonix nor the rights of others All trademarks registered trademarks and trade names used in this user s manual are the property of their resp...

Страница 3: ...Workstation 12 3 1 5 Top View Workstation 12 3 1 6 Sun Shade and Yoke Custom Option Only 13 14 3 2 Connectors 15 3 2 1 Workstation 15 3 2 2 Connector Pinouts 16 17 3 3 Front Panel 18 3 4 Specificatio...

Страница 4: ...ess Map 41 9 2 System Memory Mapping 42 9 3 Interrupt Assignments 42 10 Flat Panel Display Characteristics 43 10 1 Overview 44 11 Troubleshooting and Quick Reference Guide 44 45 12 Resistive Touchscre...

Страница 5: ...ack please send us a message using ourWeb site www azonix com under Technical Support Detail any errors you find We will correct the errors or problems as soon as possible Thank you 1 4 Trademarks Bar...

Страница 6: ...ements when notified by Buyer during a period of twelve 12 months after shipment by Seller except for spare parts which are warranted for ninety 90 days after shipment To invoke the warranty set forth...

Страница 7: ...O ANY DEFECT IN ANY PRODUCTS INCLUDING WITHOUT LIMITATION ANY A IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR USE OR FITNESS FOR A PARTICULAR PURPOSE B ANY IMPLIED WARRANTY ARISING FROM COURSE OF...

Страница 8: ...hether the unit is Warranty or Non Warranty If the unit is Warranty no method of payment will need to be entered Please enter all data requested When the process has been completed you will receive a...

Страница 9: ...un risque de l sions corporelles contre les risques lectriques et explique comment viter le probl me ALTERNATING CURRENT MISE LA TERRE The Protective Conductor Terminal Earth Ground symbol indicates...

Страница 10: ...luding HAZLOC areas the Barracuda offers ultra reliable operation backed by hundreds of hours of testing and full compliance with multiple Military and HAZLOC standards The workstation version integra...

Страница 11: ...stic fiber drivers EoPOF Second serial port Horn driver board AC source DC 24V Heaters for 40C operation DC source DC 24V Heaters for 40C operation DC DC power supply 9 36VDC Larger capacity 1 8 SSDs...

Страница 12: ...r s instruction manual may cause harmful interference with radio communications This equipment has been tested and found to be within the limits for a Class A digital device pursuant to Part15 of the...

Страница 13: ...DRAFT 16 September 2014 9 INM 19 102156 A 3 INTRODUCTION 3 1 Product Description 3 1 1 Front View and Layout Dimensions...

Страница 14: ...DRAFT 16 September 2014 10 INM 19 102156 A 3 1 2 Side View Workstation...

Страница 15: ...DRAFT 16 September 2014 11 INM 19 102156 A Rear View Workstation 3 1 3 Rear View Workstation...

Страница 16: ...DRAFT 16 September 2014 12 INM 19 102156 A 3 1 4 Bottom View Workstation 3 1 5 Top View Workstation...

Страница 17: ...DRAFT 16 September 2014 13 INM 19 102156 A 3 1 6 Sun Shade andYoke Custom Option Only Preliminary Views...

Страница 18: ...DRAFT 16 September 2014 14 INM 19 102156 A Preliminary Views...

Страница 19: ...rk Thoroughly read the Precautions section before connecting any external peripheral devices to your system Make sure the unit is turned Off before connecting any cables After you make the connections...

Страница 20: ...Pin Name Description 1 VCC 5 VDC 2 D Data 3 D Data 4 GND Ground Pin Name Description 1 TX Transfer Data 2 TX Transfer Data 3 RX Receive Data 4 n c Not connected 5 n c Not connected 6 RX Receive Data...

Страница 21: ...a E CTS Clear to send F TXD Transmit data G ISO24 Horn plus H DTR Data terminal ready I GND Signal ground J ISO Ret Horn minus Amphenol I O Circular Conn RS232 RS422 RS485 Comments A DSR RTS B DCD TX...

Страница 22: ...A 3 3 Front Panel LEDs Icon Color Description Green Power on LED Yellow HDD Active LED Orange Heater ON LED Blue LCD Touch OFF LED Buttons Icon Description LCD Touch On Off Button Brightness Up Down...

Страница 23: ...DS internal connection supporting a single 18 24bit dual channel LVDS panel Supports 24 bit dual channel LVDS panel Ethernet Function 1x Intel 82583V PCI Express Gigabit Ethernet Audio Function Sound...

Страница 24: ...Panel power consumption 1 35 Typ W 14 Weight 1350g g 3 3 3 Power Supply Specifications The Barracuda is supplied with a high efficiency 100W switching power supply unit which is EN61000 3 2 3 complian...

Страница 25: ...h 4 84 Unit Weight 20 lbs without power supply 23 5 lbs with power supply 3 3 5 Installation Certification Requirements Requirements Pollution Degree 2 Installation Category II Max Operating Altitude...

Страница 26: ...overall life span of any electronic device is shortened when operated at its highest rated temperature Leave all covers in place at all times during operation The covers protect the user against high...

Страница 27: ...AC power cable s copper core cross section should be at least 1 5mm2 per wire ALTERNATING CURRENT MISE LA TERRE To prevent electrical shock the Safety Earth Ground location on the rear as indicated b...

Страница 28: ...onnexion 1 Before installing the unit bench test by connecting all data and power connections Turn On the power After the adjustments have been made turn Off the power and disconnect the cabling 2 Car...

Страница 29: ...the system unit first Then connect the other end into a grounded AC power source 3 After the system is connected to a power source apply power to the system using the user accessible breaker press the...

Страница 30: ...em by pressing the Ctrl Alt Del keys You will want to enter the BIOS Setup Utility for the following reasons Changing components for example if you add a hard disk or memory If you do not run the Setu...

Страница 31: ...ly F7 Key Load the default F8 Key Reserved F9 Key Reserved F10 Key Save all the CMOS changes Main menu only 4 3 Obtaining Help Press the F1 key to display a small Help screen that describes the approp...

Страница 32: ...a Associates Limited UK Figure 1 or Yoda Alarm family devices for example YO5 Figure 2 The IS horns can only be connected to the Barracuda if the internal Horn Board option is purchased Please contact...

Страница 33: ...ng the horn upwards will cause the horn to become clogged with water or dust effecting performance NOTE Local codes of practice may override certain installation aspects NOTE Installation in accordanc...

Страница 34: ...ore wire can be used to the maximum length allowed 138 meters 448 feet or by calculation for the selected cable 3 The connection cable capacitance plus any other capacitance must not exceed 83nF Co 83...

Страница 35: ...0mW Ci 0 Li 0 Ingress protection IP66 with a sealed cable gland 48 programmable alarm tones Figure 4 Beka Horn internal power connection terminal Yoda hornYO5 ISC T4 NOTE Example only Consult manufact...

Страница 36: ...e below Figure 7 Connection to Barracuda 15 both versions Pin Name Description A DSR Data set ready B DCD Data carrier detect C RTS Ready to send D RXD Receive data E CTS Clear to send F TXD Transmit...

Страница 37: ...rly connected to a grounded outlet and is receiving power 2 The system begins the POST test This test verifies that the system memory systeboard hard disk drive and any other external peripheral devic...

Страница 38: ...e component activated during that step may be faulty Contact Azonix technical support for help or advice if the Start up sequence cannot be entirely executed 8 If the system issues any error messages...

Страница 39: ...dim screen Activated screensaver Disable screen saver Brightness set too low Turn up the Brightness control Display disabled Push the LCD ON blue Button Display not turned On Push On the power switch...

Страница 40: ...r An error message may be followed by a prompt to press F1 to continue or to press Del to enter Setup Each error message is accompanied by an explanation or a solution Refer to your system board manua...

Страница 41: ...onflict between a software application and your device drivers Is there an Interrupt conflict between your devices Does your software program require any extra hardware devices Are there any special m...

Страница 42: ...ver usually COM1 If the mouse cursor does not move or it is moving erratically remove the mouse ball and clean it and the rollers Use a cotton swab moistened with surgical alcohol to clean the rollers...

Страница 43: ...not to scratch or press hard with any object on the touch screen surface By doing so you may easily damage the PET surface Shade the display from direct sunlight To protect your display against burn...

Страница 44: ...ng the Barracuda Casing Use the following procedure to clean the Barracuda CAUTION ATTENTION Before cleaning the Barracuda make sure the power is turned Off and the power cord is disconnected otherwis...

Страница 45: ...errupt Controller 1 040h 05Fh SystemTimer 060h 06Fh Keyboard Controller 070h 07Fh RealTime Clock NMI 080h 09Fh DMA Page Register 0A0h 0BFh Interrupt Controller 2 0F0h DMA Controller 2 0F1h Clear Math...

Страница 46: ...0 FFFDFFFF System Memory FFFE0000 FFFFFFFF 128K On Board BIOS ROM 8 3 Interrupt Assignments There are a total of 15 IRQ lines available on the system board Peripheral devices use interrupt request lin...

Страница 47: ...reens and the manufacturer s actual ability to produce a product of near perfect quality at a reasonable price This has driven the AM LCD manufacturers to write detailed specification documents defini...

Страница 48: ...ts or inverter are not working Return for factory repair Check that the Brightness Control is at the appropriate position not at the minimum Solid white screen No Video Video signal not supplied to LC...

Страница 49: ...sh or HDD Verify no external boot device is connected Return for factory repair Barracuda is on but it is frozen My cursor is stuck on the hourglass and won t let me do anything Simultaneously press C...

Страница 50: ...citance touch sensors colloquially called Pcap or ProCap touchscreens embody the very latest features available for rugged touch sensors being constructed from solid strengthened glass sensing through...

Страница 51: ...ld be protected from the possibility of spraying water from a process or activity where this is possible While the unit is switched off the Barracuda fitted with a Pcap touchscreen can be washed down...

Страница 52: ...FT 16 September 2014 48 INM 19 102156 A 13 Certificates The Barracuda Gen2 15 Workstation is certified for Hazardous Area usage according to the following certificates 13 1 ATEX Certificate of Conform...

Страница 53: ...DRAFT 16 September 2014 49 INM 19 102156 A...

Страница 54: ...DRAFT 16 September 2014 50 INM 19 102156 A...

Страница 55: ...DRAFT 16 September 2014 51 INM 19 102156 A...

Страница 56: ...DRAFT 16 September 2014 52 INM 19 102156 A 13 2 IECEx Certificate of Conformity...

Страница 57: ...DRAFT 16 September 2014 53 INM 19 102156 A...

Страница 58: ...DRAFT 16 September 2014 54 INM 19 102156 A...

Страница 59: ...DRAFT 16 September 2014 55 INM 19 102156 A...

Страница 60: ...DRAFT 16 September 2014 56 INM 19 102156 A 13 3 AEx Certificate of Compliance...

Страница 61: ...DRAFT 16 September 2014 57 INM 19 102156 A...

Страница 62: ...DRAFT 16 September 2014 58 INM 19 102156 A...

Страница 63: ...DRAFT 16 September 2014 59 INM 19 102156 A 13 4 AEx Certificate of Compliance...

Страница 64: ...DRAFT 16 September 2014 60 INM 19 102156 A...

Страница 65: ...DRAFT 16 September 2014 61 INM 19 102156 A 14 Document Revision History Revision Date Edited by Changes 1 0 26 March 2014 KAG First draft A 25 July 2014 JMG Release...

Страница 66: ...puram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via A Meucci 10 I 20094 Corsico MI Italy Tel 39 0...