Te ch n ica l I n for m a t ion :
HOPPER U – I I cct alk
1 6
Th is con n e ct or is not ope r a t ive in t h e hoppe r s U- I I for I t a ly.
Sw it ch e s
The configurat ion of t he address of t he Hopper U- I I , as wit h ot her funct ions, is done wit h t he
dip sw it ches,
8 sw it ches locat ed on t he board which is accessible from t he underside of t he
hopper as shown in t he illust rat ion.
Figur e 1 1 . Posit ion of t h e sw it ch e s
The funct ion of t he sw it ches is show n in t he follow ing t ables.
SW 1 SW 2 SW 3 SW 4
SW 5
SW 6
SW 7
SW 8
Select ion of t he address of
t he Hopper
Not used
Select ion of t he
address m ode
Select ion of t he
working m ode
Ta ble 5 . Sw it ch e s.
-
Wit h t he swit ches 1, 2, 3 and 4 up t o 16 Hoppers U- I I can be addressed, as indicat ed in t he
follow ing t able:
cct alk
address
SW1
SW2
SW3
SW4
3 OFF
OFF
OFF
OFF
4 ON
OFF
OFF
OFF
10239 EN 03 - 2007