D-508F  digital  non-programmable  thermostat  is  designed  to  control  either 
ambient(air)  temperature  (A  Mode)  or  floor  temperature  (F  Mode)  or  a 
combination of ambient temperature with floor temperature limits(AF Mode). An 
auxiliary  remote  sensor  is  provided  to  measure  slab  temperature  in  order  to 
control the floor temperature(within maximum and minimum limits in AF Mode). It 
can also be used for sensing the outdoor temperature. 

LCD Description

INSTRUCTION MANUAL

Digital Non-Programmable Universal 

Thermostat D-508F

Radiant Floor Heating 

Installation

1. Look  for  a  location  which  has  a  constant 

temperature in the house and it is no near the 
door entry of heater or air conditioning outlet. 
The mounting height should be about five feet 
above the floor.   

2. Insert a screw driver into the slot located on the 

right  side  of  the  thermostat  to  open  the  front 
cover.

3.  Set the slide switches on the back of the control 

module  if  necessary.  Default:  AF  mode, 

°

display. 

 

4. Place  base  over  hole  in  wall  and  mark 

mounting hole locations on wall using base as 
a template.

5. Move  base  out  of  the  way.  Drill  mounting  holes  and  use  the  screws 

provided to secure the base. Use plastic anchors if necessary.

6. Through the base opening, connect wires to the terminal blocks on the 

base according to Figure 2 below.

7.  Carefully line the thermostat up with the base and snap into place. 

Wiring Diagram

R:  24VAC Hot
C:  24 VAC Common
S, S:  auxiliary remote sensor(P-01)
1, 2:   relay switch output

Note: 
The sensor wires can be 
extended by conventional wires.

R C S S 1 2

    Figure 2

R  C  S  S  1  2

Heating 
 Control

24 Vac

Input

Sensor

P-01

Slide Switch Configuration

The Slide Switches are located at the back of the control module(see Figure 1).

Temperature Display Switch(S1)

: to switch between

°

 

°

.

Mode of Operation Switch(S2):

A:  controls and displays the ambient temperature. Optional: connect external 

sensor(P-01) for the display of outdoor temperature in the upper LCD - also 
set Outdoor Sensor to ON in the setting mode. 

F:

controls  and  displays  the  floor  temperature.  Connect  external  slab 
sensor(P-01). Also displays current ambient temperature in the upper LCD. 

AF: controls  and  displays  the  ambient  temperature.  Maintains  the  floor 

temperature within desired maximum and minimum limits. Connect external 
slab sensor(P-01). Also displays current floor temperature in the upper LCD.

I

!

!

C and F

C

F

AF  F   A

    Figure 1

Setting Temperature(Setpoint)

Room

885

° °

F C

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE

VIEW  MODE

Backlit: On Off Auto

885

Room

Floor

OutDoor

888.

8

888

Floor  Max Min

Set

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE

VIEW  MODE

Backlit: On Off Auto

888

Room

Floor

OutDoor

Current Temperature

Backlit mode

Unit of measure

Keypad lock

Operation Mode(A, F or AF)

Heat contact is ON

Operation Mode
(eg. F Mode)

Current Temperature of
indicated area (eg. Room)

Current Temperature of
indicated area(eg. Floor)
related to 
operation mode

System Mode

Down Key

Up Key

Set Key

Power Key

Home Screen Display During Operation

Power-up

As soon as the thermostat is powered, all the LCD segments are displayed. 

Then it undergoes a series of tests before displaying the actual 
temperature.

SETTING THE THERMOSTAT

QuickSet  Feature:

Quickset allows the user to change the setpoint temperature instantly without 
entering the setting mode.   Simply press 

UP 

(increase) or 

Down 

(decrease) 

key during the normal operating mode. When the 

Up/Down

 key is pressed, the 

setpoint is flashing on the upper right hand corner of the LCD display to indicate 
that  the  setpoint  value  can  be  changed.  Press  the 

UP/Down  k

ey  again  to 

adjust the setpoint (press and hold for auto repeat function). Just walk away 
when finish and it will return to normal operating mode after 30 seconds. 

Setting Mode:

General Note:

!

Press and hold the 

Up 

Key or 

Down 

Key to change the value continuously 

(auto repeat function). 

!

To return to normal operating mode from the setting mode, press and hold 

the 

SET 

key for 3 seconds. However, the system also returns to normal 

operating mode if no key is pressed for 30 seconds.

!

During the setting mode, symbol “SET MODE” is displayed on the upper 

left corner of the LCD. Each time 

SET 

key is pressed, the data will be saved 

into  the  EEPROM  and  advance  to  the  next  setting(parameter).  If  no 
change of value is required, just press 

SET 

key once to go to the next step 

(parameter).

Floor Minimum and Maximum limits(AF Mode only)

The thermostat generally turns On or Off to control the ambient temperature. 
However,  if  the  floor  temperature  drops  below  the  set  minimum  floor 
temperature limit, the thermostat will turn heating On regardless of the ambient 
temperature.  If  the  floor  temperature  rises  above  the  maximum  limit,  the 
thermostat  will  turn  heating  Off  regardless  of  the  ambient  temperature  to 
maintain the floor within the desire limit.

This setting ensures a minimum floor temperature at all times. The maximum 
limit is to avoid damage to your floor and for added safety.
Note:  The  floor  minimum  limit  cannot  be  set  to  a  higher  value  than  the 
maximum limit.

Do Not

Use

Room

885

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE

VIEW  MODE

Backlit: On Off Auto

885

Room

Floor

OutDoor

888.

8

888

Floor  Max Min

Set

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE

VIEW  MODE

Backlit: On Off Auto

888

Room

Floor

OutDoor

Indicates if current
temperature is Floor
or Room(Ambient)

Shows during 
SET MODE

Shows during 
VIEW MODE

Default: F

Default: AF

24Vac
Circuit

Isolated

End

Switch (2A)

(S1)

(S2)