Azbil RYY792 Series Скачать руководство пользователя страница 1

AB-6484 

© 2004-2018 Azbil Corporation. All Rights Reserved.

 

Specifications/Instructions 

 

Converter 

 

 
General 

Model  RYY792X  series  of  converters  offer  compact, 
space-saving,  easy  installation  with  its  plug-in  structure.  
Each model is modularized for a particular function.  Model 
RYY792X  converters  can  be  used  for  signal  transmission 
between instruments, as a controller, for monitoring, and for 
various other applications. 

 

Features 

 

Compact, space-saving, plug-in structure. 

 

Minimal mounting space. 

 

Wide variety of converter types. 

 

Specifications 

Items 

Specifications 

Power 

85 V AC to 264 V AC, 50 Hz / 60 Hz 

Insulation 
resistance 

100 M

 or over at 500 V DC 

(Between input/output and power supply) 

Withstand voltage 

2000 V AC for one minute 
(Between input/output and power supply) 

Rated operating 
conditions 

Temperature: 
Humidity: 
 
Altitude: 
Vibration: 

 -5  

C to 55 

5 %RH  to 90 %RH 
(Non-condensing)  
2,000m or lower 
4.9 m/s², 5 Hz to 100 Hz 

Ambient storage & 
transportation 
conditions 

Temperature: 
Humidity: 
 
Vibration: 

-10 

C to 60 

5 %RH to 90 %RH 
(Non-condensing) 
9.8 m/s², 0 Hz to 60 Hz 

Product 
specifications 

Refer to 

Product Specifications

Dimensions 

Refer to Figs. 1 and 2. 

Accessory 

Socket (See Fig. 2.) 

Auxiliary part 

Socket: Part No. RYY-CS3700-11P 
(Though the socket is supplied with Model 
RYY792X, the socket can separately be 
ordered as an auxiliary part.) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions 

 

 

 

 

 

 

 

 

 

 

Figure 1.  Dimensions (mm): With the socket assembled 

 

 

 

 

 

 

 

 

 

 

Figure 2.  Dimensions (mm): Socket in front 

 

Potentiometer knob for SPAN adjustment 
Potentiometer knob for ZERO adjustment 

Main unit fixing screw 

25 

84 

33 

6        18.4       3

5.2 

84 

86 

84

Main unit 

Socket 

30.5 

40.5 

4.2 

7.5 

9.5 

29 

Slit for wall mounting 
(with M4 screw) 

4.2 

Slit for wall mounting 
(with M4 screw) 

Input/output terminals 

Содержание RYY792 Series

Страница 1: ...power supply Rated operating conditions Temperature Humidity Altitude Vibration 5 C to 55 C 5 RH to 90 RH Non condensing 2 000m or lower 4 9 m s 5 Hz to 100 Hz Ambient storage transportation conditio...

Страница 2: ...tact Azbil Corporation Particularly when the product is used in the following applications where safety is required implementation of fail safe design redundant design regular maintenance etc should b...

Страница 3: ...ral instructions WARNING Before wiring be sure to turn off the power to this product Failure to do so may result in electric shock or device failure CAUTION Use this product under the operating condit...

Страница 4: ...to 20 mA 250 4 to 20 mA 3 750 or lower 0 1 FS 3 0 15 With insulation 2 input high selector RYY792H3091 High selector 4 to 20 mA 250 4 to 20 mA 3 750 or lower 0 1 FS 3 5 0 15 With insulation 2 input l...

Страница 5: ...put low selector Model RYY792L 3092 24 V DC power supply Model RYY792D 3001 V I converter Model RYY792V3021 3022 3023 3024 Ratio bias Model RYY792B3081 Reverser Model RYY792A3100 Isolator Model RYY792...

Страница 6: ...output is set to 20 mA Figure 4 Front panel of the POT I converter Monitor switch setup Monitor switch is set by turning the front thumbwheel switches with a driver Output 1 is for high alarm and Out...

Страница 7: ...00 X Input signal approx 10 to 120 B Bias 100 to 100 F 100 Fine adjustment Follow the procedure below for fine adjustment 1 Under the equation Xo KX B positive gradient or Xo KX B F negative gradient...

Страница 8: ...high reliability Do not disassemble or remodel Inspection and Maintenance Inspect each setting every 2 years Install this product in a panel cabinet Additionally always keep the panel cabinet accessib...