5-13
Chapter 5. ADVANCED OPERATION
Parameter setup item list
No.
Display
Description
Factory Setting
Setting Range
Related
Function
Setup
Remarks
1
0.R G
*
1
Flow rate OK
judgment range
2 % FS
(0.02) *
14
0.5 to 100% FS
(0.005 to 1.00)*
14
C-07
C-08
C-22
C-15
C-16
Unit: L/min (standard)
2
0.HY5
*
1
Flow rate OK
judgment hysteresis
1 % FS
(0.01) *14
0.5 to 100% FS
(0.005 to 1.00)*
14
3
a.
HI
*
2,
*
3
Flow rate deviation
upper limit alarm
10 % FS
(0.10) *14
0.5 to 100% FS
(0.005 to 1.00)*
14
4
a.H.HY
*
2,
*
3
Flow rate deviation
upper limit alarm
hysteresis
2 % FS
(0.02) *14
0.5 to 100% FS
(0.005 to 1.00)*
14
5
a.
lO
*
2,
*
3
Flow rate deviation
lower limit alarm
10 % FS
(0.10) *14
0.5 to 100% FS
(0.005 to 1.00)*
14
6
a.L.HY
*
2,
*
3
Flow rate deviation
lower limit alarm
hysteresis
2 % FS
(0.02) *14
0.5 to 100% FS
(0.005 to 1.00)*
14
7
a.DLY
*
4
Flow rate deviation
alarm/valve amper-
age alarm judgment
delay time
10.0 s
0.5 to 999.9 s
C-
16
C-20
C-15
C-16
C-20
8
E.1.dL
*
5
Event output 1 delay
0.0 s
0.0 to 999.9 s
C-08
C-07
C-08
Delay does not apply to
totalizer pulse output.
9
E.2.dL
*
5
Event output 2 delay
0.0 s
0.0 to 999.9 s
10
C.F.
*
6
User set gas type
conversion factor
1.000
0.100 to 9.999
C-26
C-18
C-26
11
a.1.HI
*
7
Valve amperage
upper limit alarm
100.0 %
0.1 to 100.0 %
C-20
C-16
C-20
At the factory setting,
alarms are not detected.
12
a.1.lO
*
7
Valve amperage
lower limit alarm
0.0 %
0.0 to 99.9 %
13
E.1.5P
*
8
Event output 1
upper/ lower limit
flow rate setup
0% FS
(0.0) *
14
0 to 100 % FS
(0.0 to 1.00) *
14
C-07
C-08
Unit: L/min (standard)
14
E.2.5P
*
8
Event output 2
upper/ lower limit
flow rate setup
0% FS
(0.0) *
14
0 to 100 % FS
(0.0 to 1.00) *
14
15
raP.1
*
9
SP ramp control
slope 1
MQV9020/9050:
0.00
MQV9500:
0.0
MQV0005:
0.000
MQV0010/0050:
0.00
MQV0200:
0.0
MQV9020/9050:
0.00 to 99.99
MQV9500 :
0.0 to 999.9
MQV0005 :
0.000 to 9.999
MQV0010/0050 :
0.00 to 99.99
MQV0200:
0.0 to 999.9
C-27
Sets the flow rate change per
second.
Flow rate unit: L/min
(standard)
(mL/min (standard) for the
MQV9020/9050/9500)
Ramp control does not func-
tion if the value stays at the
factory setting (slope zero).
(The SP takes effect immedi-
ately after a change.)
16
raP.2
*
9
SP ramp control
slope 2
17
a.5cl
*
10
Analog scaling
100 % FS
(1.00) *
14
10 to 100% FS
(0.10 to 1.00) *
14
C-28
Sets the flow rate corre-
sponding to 100 % of ana-
log input / output (5 V).
Unit: L/min(standard)
18
E.a.lO
*
11
Totalized flow event
setting (last 4 digits)
0
0 to 9999
C-07
C-08
C-
13
The unit (decimal point
position) may vary de-
pending on the model.