Azbil Corporation
Instrument installation
Model MCB10A 2-17
Installing method (1) on a metallic pipe
Introduction
The installing method shown on this page is applicable to the following combination
of pipe and grounding ring materials. For installing methods applicable to other
combinations, refer to the table on page 2-13.
Pipe: Metal
Grounding ring: SUS material
Necessary components
Provide the following components:
• Through bolts and nuts
•
Centering fixtures
•
Gaskets: The recommended gaskets are gasket made of PTFE or rubber.
Recommended gasket internal diameter: Refer to Table 2-2 on page 2-12.
Installing
• Install as shown below.
For the tightening torque, follow Table 2-1 on page 2-9 irrespective of gasket
material. For the gasket internal diameter, follow Table 2-2 on page 2-12.
CAUTION
When rubber gaskets are used, the tightening torque must be small. However, this
may give rise to an insufficient surface pressure between the lining and grounding
ring, resulting in fluid leakage and injury.
Lining
Grounding ring
Gasket
Pipe side flange
Figure 2-12 Grounding ring of SUS material