3-2
3.1 Before installing electromagnetic flowmeter
Criteria for selecting the installation environment Getting started Select the optimal
location for installing the device according to the following criteria in order to maximize
its performance.
Note:
-Install the device in a location with an ambient temperature of -25 °C to 60 °C (-13 °F
to 140 °F) and an ambient humidity of 5 to 100% RH to prevent device malfunction or
output errors.
-DO NOT install the device near high-current power lines, motors, or transformers to
prevent damage from electromagnetic induction, which can cause device malfunctions
or output errors.
-DO NOT use the device to ground a welder. Doing so can damage the device.
-Be sure to ground the welding power transformer when welding near the device.
-DO NOT install the device in an area with severe vibrations or in a corrosive
environment. Doing so may cause damage the device.
-DO NOT install the device in a location subject to direct sunlight, wind, or rain.
WARNING
Use this product under the conditions as defined in the specifica-
tions (e.g., protection against explosion, pressure rating, temperature,
humidity, voltage, vibration, shock, mounting direction, and atmo-
sphere) to avoid failure of the device or harmful physical effects such
as fire damage.
WARNING
In case of the installation in the hazardous area, select the explosion-
protected apparatus. Do not use the non-explosion-protected appara-
tus in the hazardous area.
Содержание MagneW Plus+ MGG14C
Страница 6: ...iv ...
Страница 8: ...vi ...
Страница 11: ...1 3 Figure1 3 System using a Foundation Fieldbus ...
Страница 14: ...1 6 The following table is a summary of the functions of each of the keys ...
Страница 20: ...1 12 CALIBRATION OFF SHIPPING INFO OFF MAINTENANCE MODE MODE RETURN BASIC SETUP Figure1 10 MAINTENANCE MODE ...
Страница 26: ...2 6 ...
Страница 42: ...4 6 ...
Страница 78: ...A 10 ...
Страница 105: ......
Страница 108: ......
Страница 110: ......