1-7
Chapter 1. ETHERCAT COMMUNICATION
1 - 4
Displays
The status of EtherCAT communication and the node address can be shown on the displays of the controller. Set the
controller’s operation state to RUN and select the EtherCAT communication status check display
Note
•
4-2, “Changing the Display” in K1G Series High-Accuracy Position Sensor
User’s Manual (CP-SP-1385E) ,or K1G Series High-Accuracy Position Sensor
Global Model User’s Manual (CP-SP-1397E))
EtherCAT status display
Link status display
■
EtherCAT communication status check display
There are two modes for this display.
•
EtherCAT status display
Display 1:
Shows the measured process value from the selected channel.
Auxiliary display: Shows the status of EtherCAT communication.
Display 2:
Shows the node address.
•
Link status display
Display 1:
Shows the measured process value from the selected channel.
Auxiliary display: Shows the link status of the RJ-45 IN connector.
Display 2:
Shows the link status of the RJ-45 OUT connector.
To switch display modes, press
or
.