![Azbil F7M Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/azbil/f7m/f7m_user-manual_3042662040.webp)
3-14
Chapter 3. HOW TO USE THE LOADER
[Parameters] tab
Parameters
Unit
Description
Factory default
DI settings
DI function
–
Zero point adjustment
Error reset
Liquid type selection*
Error reset
DO settings
DO function
–
Flow rate event 1
Flow rate event 2
Error indication output
Totalizer pulse output
Flow rate event 1
DO polarity
–
Direct (normally open)
Reverse (normally closed)
Direct
Totalizer pulse flow
rate
mL/pulse 0.01, 0.1, 1, 10
0.1
Upper limit validity
–
Invalid
Valid
Valid
Flow rate upper limit
% FS
0.00–100.00
100.00
Hysteresis upper limit
% FS
0.00–10.00
0.00
Delay upper limit
s
0.0–60.0
0.0
Lower limit validity
–
Invalid
Valid
Valid
Flow rate lower limit
% FS
0.00–100.00
0.00
Hysteresis lower limit
% FS
0.00–10.00
0.00
Delay lower limit
s
0.0–60.0
0.0
Analog output
settings
Span correction factor
–
0.000–2.000
1.000
Zero-point correction
V
-1.000 to +1.000
0.000
Output at error
–
Present value
Last good value (before error)
Specified value (set in [Voltage at error])
Present value
Voltage at error
V
0.600–6.000
0.600
Flow rate
correction
Flow rate CCF 1
–
These parameters cannot be changed
using the [Write parameters to the
device] menu. Write the settings from
the [Monitor] tab.
1.000
Zero point adjustment
1
mW
0.00
Flow rate CCF 2*
–
1.000
Zero point adjustment
2*
mW
0.00
Offset correction value
mL/min -10.00 to +10.00
0.00
Low-flow cutoff value
% FS
0.0–100.0
1.0
Filter time constant
s
0.0–60.0
0.0
Function
settings*
Automatic setting of
flow rate correction
factor (CCF)*
–
ON
OFF
OFF
Temperature-based
correction (for water)*
–
ON
OFF
ON
Display ON/OFF using
DI status*
–
ON
OFF
OFF
*Available on devices with ID code “b” or later