2-4
Sqeeze screw
Lubricator handwheel
RC1/4
Fig. 2-2. Lubricator (Class 600 or under)
Lubricating Procedure
Step
Procedure
a
Prepare grease of the type indicated on the nameplate.
b
Tightly close the lubricator handwheel.
c
Remove the squeeze screw, apply grease, then reset the squeeze screw.
d
Loosen the lubricator handwheel and drive the grease by turning the squeeze
screw.
e
Repeat the procedure of (b), (c) and (d) until turning of the squeeze screw
becomes stiffer. Tightly close lubricator handwheel.
(5) When pressuring the valve, check that there is no leak from the gasket sections between
the valve body and process pipe. If leakage is found, tighten the nuts. (Especially when
the process fluid temperature is 400°C or higher, tighten the nuts again after raising
temperature of the valve so that it may be in serve for a longer period without requiring
immediate maintenance service.) Standard tightening torques are given in Table 2-2 on
page 2-1, Table 4-1 on page 4-4.
(6) When raising the temperature to a valve which is used for high temperature service, raise
the temperature gradually (standard rate is 100°C per hour) and do not operate the valve
while the temperature is being raised.