USER MANUAL
AYM-12P
Страница 1: ...USER MANUAL AYM 12P...
Страница 2: ...ematic Diagram 38 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from un cont...
Страница 3: ...components that produced by other manufacturers 6 After verification the problem or dispute is caused by the quality specification or majeure 7 The damage is caused by natural calamities bad using en...
Страница 4: ...e appliance read the service manual first Appliance filled with flammable gas R290 Appliance shall be installed operated and stored in a room with a floor area larger The appliance shall be stored in...
Страница 5: ...nto the air conditioner Do not repair or disassemble the air conditioner by yourself Do not put or hang dripping objects above the air conditioner Keep children from playing or climbing on the air con...
Страница 6: ...onment During operation close doors and windows to improve cooling effect Please keep air inlet and air outlet clean no obstacles to avoid noise and vibration Please put the air conditioner at smooth...
Страница 7: ...scharge pipe 11 Joint B C 12 Remote controller hook 6 Part s Name Installation accessories can t be discarded NOTICE 1 2 3 4 11 10 9 6 7 8 5 12 7 Filter 8 Air inlet 9 Joint A Remote controller FAN AUT...
Страница 8: ...will give out a sound After that you can operate the air conditioner by the control panel Under ON status after each pressing of the button on control panel the air conditioner will give out a sound M...
Страница 9: ...5 hour by pressing or button within 10 hours while timer setting will increase or decrease 1 hour by pressing or button beyond 10 hours After timer setting is finished the unit will display temperatu...
Страница 10: ...tion time Condensation may form on the louvers Do not adjust the horizontal louvers to the lowest or the highest position in the 2 Left right air flow direction Hold the vertical louver as shown in th...
Страница 11: ...gnal Make sure nothing such as curtains blocks the The signal effective distance is 8m Do not expose the receiver window to direct sunlight Use of certain fluorescent lamp in the same room Do not leav...
Страница 12: ...e X FAN is same with BLOW 9 TEMP button 10 TIMER button 11 TURBO button 12 SLEEP button 13 LIGHT button 7 HEALTH SAVE button 6 button FAN OPER AUTO HEALTH AIR FILTER TURBO ON OFF X FAN HOUR HUMIDITY U...
Страница 13: ...for heating mode Introduction for buttons on remote controller Note After putting through power air conditioner will give out a sound and operation indicator is ON red indicator the colour is differe...
Страница 14: ...high medium or low speed according to ambient temperature Fan speed under dry mode is low speed 5 Press this button to start or stop up down swing function The remote controller defaults to simple sw...
Страница 15: ...e controller it s auto swing Horizontal louver of air conditioner will swing left right automatically at the maximum angle When selecting position swing Horizontal louver of air conditioner will stop...
Страница 16: ...or unit displays indoor ambient temperature When selecting by remote controller temperature indicator on indoor unit displays outdoor ambient temperature SAVE function Under cool mode press SAVE butto...
Страница 17: ...isappear Press this button again to turn on the light for indoor unit s display icon on remote controller will be displayed Child lock function Switchover function for temperature display Press and bu...
Страница 18: ...tion 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall D...
Страница 19: ...dust on the surface of outer case please use soft towel to wipe it If the outer case is very dirty such as grease please use neutral abluent to wipe it a Press the clasp as shown in the fig and then...
Страница 20: ...t and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5 Check whether window bracket is damaged or not If yes please contact d...
Страница 21: ...losed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit is restarted up after stopping immediately Wait after power recovery...
Страница 22: ...cold air air conditioner will delay for a while to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting will resume operation No air blowed out from ai...
Страница 23: ...in the unit ERROR CODE and high humidity environment if ambient temperature is too high power off the unit and then energize it for operation after the ambient temperature drops to 35 below blocked by...
Страница 24: ...y Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supply circuit 3 For appliances with type Y a...
Страница 25: ...x Zsys unit ohms AYM 12P 0 12 To be in compliance with IEC 61000 3 11 impedance value of power supply system Zsys 11 connected to product must be less than or equal to the allowable maximum value of i...
Страница 26: ...A joint B joint C drainage pip user s manual battery AAA 1 5V screw wire hook Drain connector heat discharge pipe Optional Window kit Bracket Rain guard Insect guard net Window panel Exhaust cover Adj...
Страница 27: ...re Hook Assemble the wire hook at the back of the unit with screws the direction of wire Wind the power cord around the wire hook direction of wire hook is upward direction of wire hook is downward sc...
Страница 28: ...t NOTICE When using the continuous drainage option from the bottom hole install drainage pipe as follow before using otherwise poor drainage will affect normal operation of the unit There are 2 ways t...
Страница 29: ...e small pan or a suitable place Once draining is complete re install drain cap Press ON OFF button to restart the unit 1 In Cool or Dry mode operating the condensation water will be drained to the cha...
Страница 30: ...hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose installation may result i...
Страница 31: ...guards to the insect guard net Insert all three projections on each rain guard into the holes in the insect guard net 2 Attach the guard combined above to the window panel Push the insect guard net fi...
Страница 32: ...1 Open the window sash and place the window panel on the window sill 2 Slide the adjustment panel to fit the window frame width 3 Secure the window panel to the sill with screws Inner width of the win...
Страница 33: ...e the window sash securely against the Window panel 7 Attach the bracket with a screw Recommended Please lay a tabular material underneath the window panel in case you could not attach the rain guard...
Страница 34: ...sect guard net Insert all three projections on each rain guard into the holes in the insect guard net 2 Attach the guard combined above to the window panel Push the insect guard net firmly to ensure t...
Страница 35: ...he window frame 2 Slide the adjustment panel to fit the window frame height 3 Secure the window panel to the window frame with screws Inner height of the window 38 5 980mm 59 1500mm Use the window pan...
Страница 36: ...a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep window sill Bracket Installation in a sliding sash window Opt...
Страница 37: ...harge pipe clockwise clockwise joint A joint B C heat discharge pipe 2 Insert joint A of heat discharge pipe the side with TOP is upwards into the groove until you hear a sound 3 Lead the exhaust hose...
Страница 38: ...arge pipe correct correct correct wrong The length of the heat discharge pipe is less than 1m It is recommended to use it with shortest length the pipe or connect it with other When installing heat di...
Страница 39: ...t discharge pipe 2 Remove joint B C from 1 Remove joint A Press the clasp and lift joint A upwards to outdoors remove it upwards clasp disassemble joint A would easily cause malfunction Installation a...
Страница 40: ...nstallation and Disassembly of Heat Discharge Pipe 37 PUSH PUSH Operation Test Put through the power supply and then press ON OFF button on remote contro ller to start the unit Press mode button to se...
Страница 41: ...ATER BU C DISP1 YEGN COMP DISP2 S PE AP4 REC RD CAP YE ROOM TUBE OUTTUBE HIGH WP OFAN FAN RD C1 BK BK RT1 RT2 RT3 SA M2 YEGN M1 YEGN PE RD CAP BN PE RD CAP BN C3 C2 38 AP2 MAIN BOARD2 FAN1 AC L K201 1...
Страница 42: ...d Kingdom www sinclair world com The device was made in China Made in China REPRESENTATIVE SERVICE SINCLAIR Global Group s r o Purky ova 45 Brno 612 00 Czech republic Phone sales 420 541 590 140 Phone...
Страница 43: ......