0 4
EN
A S S E M B L Y (see page 39)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The product is not designed to be used with steam baths!
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ Observe all current and water lines when drilling!
⁄ The performance of the waste must be of sufficient size.
⁄ The shower may only be connected downstream of a shut-off valve or sanitary
fitting.
E L E C T R I C A L C O N N E C T I O N
The electrical connection may only be carried out by an electrician!
Voltage supply
The system must be protected via a leakage current protective device (RCD⁄ FI) with
a measurement difference current of ≤ 30 mA.
The product must be connected to 4 mm² equipotential bonding (PA) to be
provided by the customer.
E L E C T R I C I A N
The installation and testing work must be performed by a skilled electrician in
observance of VDE 0100 part 701, IEC 60364-6 and IEC 60364-7-701 as well
as EN 60335-2-105.
The mains connection line must be inserted into the c
o
nnection socket with double
insulation
Z
.
T E C H N I C A L D A T A
Operating pressure in front of the shower fitting:
max. 0,6 MPa
Recommended operating pressure:
0,25 - 0,5 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Recommended hot water temp.:
42°C
safety lock:
40°C
W a r n i n g : E x c e e d i n g t h i s t e m p e r a t u r e c a n c a u s e b u r n s !
Thermal disinfection:
70°C ⁄ 4 min
Nominal voltage:
100-240V AC 50 -60Hz
Nominal consumption:
18W
Lights 4xLED:
12V DC SELV 4W
The lamp cannot be dimmed.
Protection class:
II
Protection category:
IPX5
Shower Heaven 970
Weight (with packaging)
47,9 kg
Shower Heaven 720
Weight (without packaging)
28,36 kg
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page48)
F L O W D I A G R A M (see page33)
I N S T A L L A T I O N E X A M P L E (see page38)
S P A R E P A R T S (see page50)
C L E A N I N G (see page56)
M A I N T E N A N C E (see page52)
Electrician
Warm water
Cold water
The waste drain performance must be more than 50 l⁄min.
Waste
Turn on water ⁄ close
Requires two persons.
Hot surface!
Safety gloves must be worn#
Eye protection must be worn
natural sponge
Decalcifier (Citric acid base)
Avoid contact with eyes and skin. If this product contacts your eyes, rinse
thorougly with water.
Electricity on ⁄ off
D I S P O S A L O F W A S T E B A T T E R I E S A N D O L D E L E C -
T R I C A L & E L E C T R O N I C E Q U I P M E N T (applicable in the
European Union and other European countries with separate collection
systems).
This symbol on the battery, the product or the packaging indicates that the battery or
the product shall not be treated as household waste. By ensuring the battery or
product are disposed of correctly, you will help prevent potentially negative conse-
quences for the environment and human health. The recycling of the materials will help
to conserve natural resources. To ensure that the battery or product will be treated
properly, hand over the product at end-of-life to the applicable collection point for the
recycling of batteries, electrical and electronic equipment. For more detailed
information about recycling of this product or battery, please contact your local Civic
Office, your household waste disposal service or the shop where you purchased the
product.
i
> 50 l/min
RAINDRAIN
F O R U K O N L Y :
Hansgrohe Ltd.
Unit D1 Sandown
Industrial Park
Esher Kt10 8BL
Surrey
Содержание ShowerHeaven 720 3jet 10625800
Страница 36: ...3 6 i DN 20 DN 20 DN 20 DN 20 DN 20 DN 15 50 l min...
Страница 37: ...3 7 i DN 20 DN 20 DN 20 DN 20 DN 20 DN 15 50 l min...
Страница 38: ...3 8 i...
Страница 39: ...3 9 12x SW 5 mm min 1m 4mm L N PE DN 20 DN 20 DN 20 X X Y Y min 1m 4x 2x 1 2 3 4 1 2 3...
Страница 40: ...4 0 SW 13 mm 12x L N PE L N PE 30 mm 1 2 10 mm 12x 4 5 6...
Страница 41: ...4 1 SW 5 mm SW 24 mm SW 20 mm 1 2 1 2 7 8 9...
Страница 42: ...4 2 10 10a SW 4 mm SW 4 mm 10 L N PE 10a 10 1 2 3 10 10621800 10625800 10623800 10627800...
Страница 44: ...4 4 1 0 1 0 1 2 3 1 2 3 14 15 16 10621800 10625800...
Страница 45: ...4 5 SW 5 mm 3x SW 4 mm 1 2 3 17 18 19...
Страница 46: ...4 6 SW 4 mm NO 6 mm 1 2 20 21 22 10621800 10625800...
Страница 48: ...4 8 7 3 6 AXOR ShowerHeaven 720 3jet 10625800 10627800...
Страница 49: ...4 9 7 3 6 AXOR ShowerHeaven 970 3jet 10621800 10623800...
Страница 52: ...5 2 SW 5 mm SW 4 mm 2x 2 1 0 1 3 2 1 3 23 24 25 10621800 10625800...
Страница 53: ...5 3 4x SW 24 mm SW 24 mm 26 27 28...
Страница 55: ...5 5 1 3 2 1 0 2 1 3 2 1 0 1...
Страница 57: ...5 7 1 2 2 1 3 4 5...
Страница 58: ...5 8...
Страница 59: ...5 9...