36
AXOR Industries
Service Manual
Nano Mack
®
ver.1 rev.11/'19
2.9 Regen resistance connections
EXTERNAL REGEN RESISTANCE connection
It is possible to use a
100W (
for the ohm
see cap. 1.3 Technical Data on page 11
)
external re-
sistance to absorb the excess of energy from decelerating or braking.
Notes
:
• The resistance must be connected to the zinced panel utilising two screws,
possibly out of the
panel or, if it is not possibly, inside the panel but as far as possible above the drive.
•
Insert the fuse
F
3
(
see cap. 1.3 Technical Data on page 11
).
• Do not mount the resistor on surfaces which can be damaged by heat.
• If the resistors are mounted externally, protect them.
MKN60/25-B-X-CB-Sxxx
X000/X000
00000000
00000000
+AT
-AT
U
V
W
USB
MKN60/25-B-X-CB-Sxxx
X000/X000
00000000
00000000
+AT
-AT
U
V
W
USB
MKN60/25-B-X-CB-Sxxx
X000/X000
00000000
00000000
+AT
-AT
U
V
W
USB
MKN60/25-B-X-CB-Sxxx
X000/X000
00000000
00000000
+AT
-AT
U
V
W
USB
RESISTANCE CABLE LENGHT > 30 cm
FUSE (F3)
FUSE (F3)
FUSE (F3)
FUSE (F3)
RESISTANCE CABLE LENGHT ≤ 30 cm