background image

 

GPI input 

connectors 

This is the pin assignment of the 37 pin ‘D’-type female (socket) 
connectors 

 
Inputs 1-16   

 

Inputs 17-32   

 

Inputs 33-48 

PIN 

SIGNAL 

 

PIN 

SIGNAL 

 

PIN 

SIGNAL 

Input 1A 

 

Input 17A 

 

Input 33A 

Input 2A 

 

Input 18A 

 

Input 34A 

Input 3A 

 

Input 19A 

 

Input 35A 

Input 4A 

 

Input 20A 

 

Input 36A 

Input 5A 

 

Input 21A 

 

Input 37A 

Input 6A 

 

Input 22A 

 

Input 38A 

Input 7A 

 

Input 23A 

 

Input 39A 

Input 8A 

 

Input 24A 

 

Input 40A 

Input 9A 

 

Input 25A 

 

Input 41A 

10 

Input 10A 

 

10 

Input 26A 

 

10 

Input 42A 

11 

Input 11A 

 

11 

Input 27A 

 

11 

Input 43A 

12 

Input 12A 

 

12 

Input 28A 

 

12 

Input 44A 

13 

Input 13A 

 

13 

Input 29A 

 

13 

Input 45A 

14 

Input 14A 

 

14 

Input 30A 

 

14 

Input 46A 

15 

Input 15A 

 

15 

Input 31A 

 

15 

Input 47A 

16 

Input 16A 

 

16 

Input 32A 

 

16 

Input 48A 

17 

0V (1-16) 

 

17 

0V (17-32) 

 

17 

0V (33-48) 

18 

0V (1-16) 

 

18 

0V (17-32) 

 

18 

0V (33-48) 

19 

+5V (1-16) 

 

19 

+5V (17-32) 

 

19 

+5V (33-48) 

20 

Input 1B 

 

20 

Input 17B 

 

20 

Input 33B 

21 

Input 2B 

 

21 

Input 18B 

 

21 

Input 34B 

22 

Input 3B 

 

22 

Input 19B 

 

22 

Input 35B 

23 

Input 4B 

 

23 

Input 20B 

 

23 

Input 36B 

24 

Input 5B 

 

24 

Input 21B 

 

24 

Input 37B 

25 

Input 6B 

 

25 

Input 22B 

 

25 

Input 38B 

26 

Input 7B 

 

26 

Input 23B 

 

26 

Input 39B 

27 

Input 8B 

 

27 

Input 24B 

 

27 

Input 40B 

28 

Input 9B 

 

28 

Input 25B 

 

28 

Input 41B 

29 

Input 10B 

 

29 

Input 26B 

 

29 

Input 42B 

30 

Input 11B 

 

30 

Input 27B 

 

30 

Input 43B 

31 

Input 12B 

 

31 

Input 28B 

 

31 

Input 44B 

32 

Input 13B 

 

32 

Input 29B 

 

32 

Input 45B 

33 

Input 14B 

 

33 

Input 30B 

 

33 

Input 46B 

34 

Input 15B 

 

34 

Input 31B 

 

34 

Input 47B 

35 

Input 16B 

 

35 

Input 32B 

 

35 

Input 48B 

36 

0V (1-16) 

 

36 

0V (17-32) 

 

36 

0V (33-48) 

37 

0V (1-16) 

 

37 

0V (17-32) 

 

37 

0V (33-48) 

 

 

 

 

 

 

 

 

 

 

Содержание Cerebrum CGP-4848

Страница 1: ...CEREBRUM CGP 4848 Cerebrum 1U General Purpose Interface unit Operation manual ...

Страница 2: ... policy as described in the general terms That means that Axon Digital Design BV can only warrant the products as long as the serial numbers are not removed Copyright 2001 2019 AXON Digital Design B V Date created 25 01 2012 Date last revised 01 04 2019 Axon the Axon logo and Synapse are trademarks of Axon Digital Design B V This product complies with the requirements of the product family standar...

Страница 3: ...uction 7 Features 7 Installation 8 Connecting the D sub connectors 8 General Purpose Inputs 8 General Purpose Outputs 8 GPI input connectors 9 GPI output connectors 10 Configuration 11 Ip settings 11 NOTE 11 Adding the CGP 4848 to the Cerebrum system 12 Configuring functionality 14 Reprogramming the CGP 4848 15 Enter Bootmode 15 Upgrading the panel s firmware 15 Specifications 17 ...

Страница 4: ...4 ...

Страница 5: ... The brains behind your many and varied workflows Cerebrum allows users to remotely Configure a complex workflow in a short space of time Manage Report events using hierarchical system status Control devices via an intuitive user friendly graphical interface Maintain a workflow over its lifetime Cerebrum employs Ethernet communication to each device in your chosen workflow providing the ability to...

Страница 6: ...s Each device in your workflow is shown in the System view and displays its current and historical status using an icon Cerebrum actively monitors each device to check for its current status The status of each device is passed to a parent node within the System view and a hierarchical status of your complete workflow is shown using a single icon This is also reflected in the application s optional...

Страница 7: ...tasks including physical GPI O s for the Cerebrum Tally and Mnemonic option or just for very simple interface to third party devices for tasks such as alarm status monitoring or control The unit uses its inbuilt 100Base T Ethernet connector to connect to the Cerebrum server over either a local or wide area network The unit can be configured to use either DHCP or manually assigned IP addresses As w...

Страница 8: ... of the input connectors can be used to provide this This output pin is current limited and will provide no more than 400mA However even if all 16 inputs use this pin then only 120mA will be drawn For instance to connect a normally open mechanical switch to trigger input GPI 1 when it is closed wire pin 19 of the input connector to one side of the switch then wire the other side of the switch to p...

Страница 9: ...t 46A 15 Input 15A 15 Input 31A 15 Input 47A 16 Input 16A 16 Input 32A 16 Input 48A 17 0V 1 16 17 0V 17 32 17 0V 33 48 18 0V 1 16 18 0V 17 32 18 0V 33 48 19 5V 1 16 19 5V 17 32 19 5V 33 48 20 Input 1B 20 Input 17B 20 Input 33B 21 Input 2B 21 Input 18B 21 Input 34B 22 Input 3B 22 Input 19B 22 Input 35B 23 Input 4B 23 Input 20B 23 Input 36B 24 Input 5B 24 Input 21B 24 Input 37B 25 Input 6B 25 Input ...

Страница 10: ...4 COM 16 Output 13 COM 16 Output 29 COM 16 Output 45 COM 17 Output 14 COM 17 Output 30 COM 17 Output 46 COM 18 Output 15 COM 18 Output 31 COM 18 Output 47 COM 19 Output 16 COM 19 Output 32 COM 19 Output 48 COM 20 Output 1 COM 20 Output 17 COM 20 Output 33 COM 21 Output 2 NO 21 Output 18 NO 21 Output 34 NO 22 Output 2 NC 22 Output 18 NC 22 Output 34 NC 23 Output 3 COM 23 Output 19 COM 23 Output 35 ...

Страница 11: ...eenshot unless explicitly instructed by Axon Support When the Current IP Address field is correct press the Connect button to read back the current settings from the unit If the application communicated with the unit then the fields for the New IP Address Use DHCP Subnet mask Gateway IP address and GPI de bounce time will reflect the settings of the unit and will be enabled for editing When the de...

Страница 12: ...to be running Cerebrum V1 07 or later To add the unit go to the Network menu and choose the Add Generic Device option from the Device Category selection choose the GPI O setting and CGP 4848 from the Device type selection Then select the configured IP address and suitable Device name for the unit and finally press the Add button The following screenshot displays this window The unit should now app...

Страница 13: ...w control of the GP outputs of the unit as shown below The Monitoring tab in the same way as all other devices within Cerebrum shows a historical log of the status events for this unit along with the status of the GP inputs and PSU s the following screenshot displays the monitoring tab ...

Страница 14: ...ebrum system The CGP 4848 device can be used as a basic status detection for third party devices for this to be used the Status severities of the unit will need to be configured using the Generic Device Status Severities dialog which can be found in the Configuration Status Severities menu within Cerebrum For more information on either of these topics please consult the Cerebrum on line help file ...

Страница 15: ...address of the device in the system view to another IP address temporarily Then select the Engineering Configure Cerebrum Hardware option under the View menu This will present a dialog as shown below Enter the IP address of the device and then press Connect When connected press the Enter Bootmode and then Cancel to quit this dialog Upgrading the panel s firmware When the unit is in this mode it wi...

Страница 16: ...ocate the required file and then press the Upload button the panel will then reprogram itself After successfully programming the unit it will then prompt the user to reset the MCU After doing this the brower will complete and the unit will reset itself after which the unit can be added back into the system by changing the IP address of the device in the system to the IP address of the unit ...

Страница 17: ... Frequency 50 60 Hz 12V DC 2 0A General Purpose Inputs Input Voltage range Typical input current 5 12Vdc 10 4 5V 13 2V 5mA 5Vdc input General Purpose Outputs Maximum Voltage Maximum Current Max Switching capacity Contact resistance Expected life 220Vdc 250Vac 2 A 60W 70mOhms 5 x 105 operations Local Output Voltage Input connectors pin 19 Voltage Maximum Current 5Vdc 10 400mA Miscellaneous Operatin...