background image

 

1.

 

Introduction 

 

The Cerebrum CCP-4200B control panel is a 1RU 19” rack mount 
hardware control panel with 42 compact LCD buttons for use with the 
Cerebrum control and monitoring system and can be configured to control 
or show the status of any device connected to the Cerebrum system.  
 
The controls can be configured into one or more sub-panels, each of which 
can use an unlimited number of linked  ‘pages’ to form a flexible quick 
and logical user interface to the system. The panel is configured using the 
Cerebrum Form Designer application in the same way as the software 
panels within the system.  
 
Each of the buttons has a 64x32 LCD matrix which can either display up to 
three rows of multi-lingual text in a chosen font and/or a graphical icon. 
One of up to sixty four different background colors and eight brightness 
levels can be selected to allow for easy differentiation of functionality, 
selection or state. 
 
Eight GPI inputs are available and can be used for any function within 
Cerebrum but most commonly are used for selection of router sources 
when driven from Camera Operator Control Panel touchdowns. 
 
The panel communicates with Cerebrum using a TCP/IP protocol over a 
local or wide area Ethernet network and can be configured to use either 
DHCP or a manually assigned IP addresses.  
As with other Axon devices when used in manual IP assignment mode the 
address, sub-net mask and gateway can be assigned using the configuration 
mode of the panel. 
 
The flush mounted LCD buttons and compact depth allows the panel to be 
horizontally mounted in a desk or console. The buttons are inserted into 
sockets allowing them to be changed in the field in the event of any 
accidental damage. 

 

 
The panel is powered with an external AC-DC brick PSU unit, which can 
be attached using the raised metalwork bridges on the rear of the panel. 
The panel has two lockable DC power inlets allowing for an optional 
redundant PSU in critical applications. 

 

 

 

 

 

 

 

 

Содержание Cerebrum CCP-4200B

Страница 1: ...CCP 4200B Cerebrum 42 LCD button control panel Operation manual ...

Страница 2: ...Hercules 28 NL 5126 RK Gilze The Netherlands Phone 31 161 850 450 Fax 31 161 850 499 E mail Info axon tv Web www axon tv OPERATION MANUAL CCP 4200B ...

Страница 3: ...on warrants their products according to the warranty policy as described in the general terms That means that Axon Digital Design BV can only warrant the products as long as the serial numbers are not removed Copyright 2001 2016 AXON Digital Design B V Date created 31 05 2016 Date last revised 31 05 2016 Axon the Axon logo and Synapse are trademarks of Axon Digital Design B V This product complies...

Страница 4: ...ents Table of Contents 4 1 Introduction 5 2 Configuration 6 Panel Configuration 6 Adding the panel to Cerebrum 7 Configuring functionality on the panel 8 GPI Contacts 8 3 Reprogramming the panel 10 4 Specifications 12 ...

Страница 5: ...entiation of functionality selection or state Eight GPI inputs are available and can be used for any function within Cerebrum but most commonly are used for selection of router sources when driven from Camera Operator Control Panel touchdowns The panel communicates with Cerebrum using a TCP IP protocol over a local or wide area Ethernet network and can be configured to use either DHCP or a manuall...

Страница 6: ...e highlighted and then using the buttons marked with the up and down arrows until the required digit is shown Each digit can be set until the required IP address is configured pressing the button showing OK will save this setting and return you to the configuration mode menu again The settings for the Subnet mask and gateway can be configured in the same way The IP Address mode can either be confi...

Страница 7: ...what the panel will show when the system starts or the panel is modified The default settings that the panels will use for the router category and view variables when restarting can be optionally defined for the panel In this way multiple panels can use the same CPF file but change their behaviour based on this information The check box for redundant PSU will make sure an alarm or warning is gener...

Страница 8: ...l provides eight GPI inputs which can be used for different functionality within Cerebrum The GPI s will show themselves in the Tally and Joystick dialogs of the Cerebrum configuration provided the panel is given a device name when adding it to the system The GPI inputs are internally fed to an optical isolator which provides an electrical isolation between the input signals applied to the unit Th...

Страница 9: ...Where pin 10 is the pin on the furthest left hand side as you view the rear of the unit The pin out of the connector is also shown on a label on the rear of the unit Serial Port The use of the RS 422 Serial port is not currently supported at the moment It will be available in future releases ...

Страница 10: ...the same for five seconds or more The panel will then display a menu with the default and bootloader options Press button 10 saying YES to the right of EXIT TO BOOT LOADER The unit after a short while will then show a single illuminated button saying BOOT LOADER When the panel is in this mode it will host a webserver at its IP address If you use a web browser and type in the IP address in the addr...

Страница 11: ...load button the panel will then reprogram itself After successfully programming the unit it will then prompt the user to reset the MCU After doing this the brower will complete and the unit will reset itself and show the normal starting UI as described above ...

Страница 12: ... 71 Depth excluding front panel including DC connector 65mm 2 55 Weight Weight including power adapter CCP 4200B 1 5kg Power AC PSU Panel input 100 240V AC 1 0A 0 5A Frequency 50 60 Hz 12V DC 4 0A General Purpose Inputs Typical input current 6 4mA Miscellaneous Operating environmental temperature 0º to 40º C 32º to 104º F Storage environmental temperature 20º to 70º C 4º to 158º F ...

Отзывы: