Axnes AS
Document number
Revision
Date
Page 4-1
Section 4:
Technical data
Technical data for MP30
4.1.1 Operation
Radio:
UHF Duplex, single frequency
UHF half duplex analogue FM modulation
VOX operation:
Axnes AS patented NIVOX, ensures no loss and
operation in high noise environment
Number of wireless users:
Unlimited
Number of groups:
2
Number of radio configurations: 20 intercom configurations, 50 analogue UHF channels
Encryption:
AXS-SW-0511 using AES-256
Operating temperature:
-20°C to +55°C with internal battery.
-40°C to +55°C with external battery
Charging temperature:
0°C to +50°C
Storage temp. (survival):
-40°C to +60°C
Storage temp. (recommended):
+10°C to +35°C
Water resistance:
Intended for outdoor use, protected from low pressure
water jets from all directions. Not intended for
submersion.
Altitude:
25000 feet
NVG:
Optional NVIS class B friendly
4.1.2 Power supply
Supply:
Internal rechargeable Li-Ion 3.6V 4700mA battery
Operating time (typ):
Standby: 30 hours
Transmit: 7 hours
Receive: 12 hours
Charging time (typ):
3 hours
Longer charge time may be expected at high and low
temperatures.
Protection:
Protection against input voltage polarity swap, over-
charge, over-discharge, over-currents, over- and under-
temperatures.
4.1.3 Headset Interface
Speaker output level:
Adjustable up to 0.5W in 8 ohm load, 1KHz test signal.
Speaker signal is ground referenced, allowing for single
ended headsets
Supported Microphones:
Dynamic, Electret, amplified Electret with automatic
microphone detection