Maintenance
20
Head Stock Adjustment
If there is sufficient play happening in the head stock
assembly, loosen the three locking nuts (E) to the side of the
head stock column and carefully adjust the gib strip grub
screws (F), see figs 38.
NOTE: make small adjustments, pulling the operating
lever down until the head stock slides smoothly up and
down the column, but not too much causing the head
stock to tighten or jam.
When you feel the slide play has been eliminated, tighten the
locking nuts (E) on the column to secure the setting.
Fig 38
E
F
General Maintenance
WARNING!! DISCONNECT THE MORTICER FROM
THE MAINS SUPPLY BEFORE CONTINUING!
To ensure optimum performance from your morticer routine
cleaning and lubrication is required.
After long periods of use, wood and resin deposits will build up
on the table and the rack and pinion gears. Clean all surfaces
using “Axcaliber Blade and Bit Cleaner Code 104736” then apply
a light application of lubricant to all moving parts using
“Axcaliber Dry Lubricant Code 503468”.
Code: 104736
Code: 503468
General Maintenance
Light Lubricate
Lubricate