background image

AX-R4 Router

Full 2-way RS232 & Ethernet control. Unlocks 
the full potential of the KPC 2.8 Touchpanel.

FEATURES

4 x Dedicated RS232 DB9 ports, max 

throughput = 115 k baud

6 x KPC 2.8 Touchpanel RJ45 ports

Ethernet RJ45 port: 10Mbs, DHCP or 
Fixed IP. DNS host name resolution 

supported. SNTP time/date 
synchronisation via internet. More 

internet services may be added in 
future.

IR routing from specific keypad ports.

4 x IR emitter output / sensor input 

3.5mm jacks. These jacks work 
concurrently as an IR output and sensor 

input.

IR emitter output level adjustment.

Realtime internal clock.

Microphone line level out, with output 
sensitivity adjustment.

2 x RJ25 Expansion ports.

IN from the previous R4 & OUT to the 
next R4.

3 x Status LED’s.

Power (green)

Heartbeat (orange)

Port Activity throughput (orange)

Powered by AX-451/452AV multi-zone 

amplifiers or 12 – 18 VDC 1.6A power 
supply.

Two way control Applets for:

Integra Tuner, CD, DVD, Receiver 

incl Z2 and Z3.

DLO docking Station

Sonance I-Pod Dock

Vantage lighting

Autonomic Controls Media Center

Vantage DMM

Clock with optional date and 
screensaver functionality.

More to come...

Please check www.axium.co.nz for 
the latest applet updates.

Approvals: C-Tick CISPR22, FCC

WIRING

The six keypad RJ45 ports can be used for 
connecting KPC 2.8 touchpanels using a 

maximum of 100 metres of CAT-5 cable. The 
port connections are freely interchangeable. 

These ports cannot be used with the AX-KPB 
and are not designed for connecting to an 

Ethernet network.

The four RS232 DB9 ports are used for 
connecting RS232 controlled equipment. The 

pin allocations follow the standard for male 
connectors, where pin 2 is R4 receive, pin 3 is 

R4 transmit and pin 5 is ground.

Standard single IR emitters are plugged into 
the IR ports and fixed to the IR window of the 

controlled equipment. The emitter current for 
each port can be increased by turning the 

potentiometers anti-clockwise.

The paging output is active when the 
microphone on a KPC 2.8 is used. This is 

connected to an input of an amplifier (typically 
source 8 on a 451/452AV or MZA-4.7). The 

potentiometer can be turned clockwise for 
increased gain.

The two RJ25 ports are used for daisy 

chaining multiple routers. This allows the 
creation of a matrix of more than six KPC 2.8s 

and/or more than four RS232/IR controlled 
devices. When two or more routers are 

chained, the RS232 and IR port numbering is 
modified so that the first router is numbered 

1-4, the second is 5-8, the third 9-12, etc. The 
“OUT” connector of the first router is 

connected to the “IN” connector of the second 

router. If a third router is used, the “OUT” 
connector of the second router is connected 

to the “IN” connector of the third router and 
so on for a total of up to six routers. The “IN” 

connector of the first router and the “OUT” 
connector of the last router is NOT used. The 

leads connected to the expansion ports shall 
not exceed one metre in length.

The green Axium port connector connects to 

an Axium 451/452AV or Integra MZA-4.7 
amplifier or amplifier stack. 12VDC is provided 

by the amplifier to power the R4. If multiple 
routers are used, only the first one can be 

connected to the Axium port and thus 
powered by the Axium port, other routers will 

need their own power supplies. Also if a stack 
of amplifiers is used, there can still be only 

one link between the amplifier stack and the 
routers using the Axium port on the first 

router.

When not using an Axium 451/452AV or 
Integra MZA-4.7 amplifier or if a higher supply 

voltage is required, a 12 – 18 VDC centre 
positive plug pack power supply is used to 

power the R4.

The Ethernet connector located between the 
RS232 and the expansion ports can be used 

for providing network and internet access to 
the R4 and connected KPC 2.8 touchpanels. 

The network must be DHCP capable unless a 
static IP address is configured. The R4 

automatically fetches the current time and 
date if the network has internet access. If 

multiple R4 routers are used, each R4 needs 
an Ethernet connection if network or internet 

features are used.

The USB connector is only used in 
combination with the R4 Manager program 

(see below).

CONFIGURATION

The default factory settings are to use DHCP 

and to synchronise the real time clock with 
time.nist.gov if an Ethernet connection is 

used. The R4 Manager program included in 
the Axium Software Suite available from 

http://www.axium.co.nz/ is required should 
other settings be required. The R4 Manager 

also offers diagnostic and firmware update 
functionality. Please see the documentation in 

the Axium Software Suite for more 
information.

TROUBLESHOOTING

No control of any equipment

Check the power LED. Check power 

supply if not lit.

Check heartbeat LED. If not flashing try 
powering the unit off and back on again.

If using a single router ensure that the 

“IN” and “OUT” ports are not used.

Ensure the correct setting is used in AKM 
under “Settings” - “Serial device” in the 

KPC 2.8 configuration. Use either “Auto 
detect” or “AX-R4 Router”.

If using a chain of routers, ensure that 

the chain has a definitive beginning and 
end and that no loop exists.

No control of specific equipment (RS232 
and IR)

Ensure that the RS232 and IR port 
connections correspond to the ports 

assigned in AKM when configuring the 
KPC 2.8.

Ensure that the correct pins for receive 
and transmit on the RS232 connection 
are used.

Some RS232 devices allow the baud rate 
and other parameters to be adjusted. 
Ensure that the settings required by the 

applet are used.

If using a chain of routers ensure that 
the port assignment rules have been 

correctly understood and applied.

Ensure that the equipment is working 
correctly and that all the connections 

and cables are sound.

No control of specific equipment 

(Ethernet)

If using an IP address, ensure that the 

address of the equipment is statically 
assigned and corresponds to the address 

assigned in AKM when configuring the 

Отзывы: