AXIS Q6055-S PTZ Network Camera
Product overview
3
Network connector (internal)
4
Network connector SFP (external) (2x)
5
Network connector RJ45 (external) (2x)
6
Camera network LED indicator
7
Network LED indicator (4x)
8
Power LED indicator
9
Ground clip
10 I/O connector (internal)
11
I/O connector (external)
12 Multicable
13 Ground screw
How to pressurize the camera (recommended)
The camera housing can be filled with Nitrogen gas to prevent condensation.
The filling process is repeated three times, releasing the pressure between fillings, to make sure that all air and humidity is purged
from the housing.
Note
The camera housing has an pressure relief valve that limits the filling pressure to 0.5 bar (7 psi). During normal use the
pressure inside the camera housing may drop below that pressure. For full protection make sure that the pressure is above
0.2 bar (3 psi) .
1. Set the regulator gauge on the gas cylinder to 0.5 bar (7 psi).
2. Remove the caps from the inlet valve and the pressure relief valve.
3. Place the chuck on the inlet valve and press down to fill the camera with nitrogen.
4. When the pressure inside the camera housing reaches 0.5 bar (7 psi) the pressure relief valve will open. Place your hand
over the pressure relief valve to verify that the gas is flowing out.
5. Lift the pressure relief valve to let the overpressure out of the camera unit.
6. Repeat the filling process a total of 3 times, leaving the the camera pressurized the last time.
7. Put the caps back on the inlet valve and the pressure relief valve.
6