background image

AXIS Q60-S Series

AXIS Q6042-S PTZ Dome Network Camera

AXIS Q6044-S PTZ Dome Network Camera

AXIS Q6045-S Mk II PTZ Dome Network Camera

E

N

G

L

IS

H

F

R

A

N

Ç

A

IS

D

E

U

T

S

C

H

I

T

A

L

IA

N

O

E

S

P

A

N

Õ

L

òò

¨¨
¾¾

Installation Guide

Содержание Q6042-S

Страница 1: ...AXIS Q60 S Series AXIS Q6042 S PTZ Dome Network Camera AXIS Q6044 S PTZ Dome Network Camera AXIS Q6045 S Mk II PTZ Dome Network Camera ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPANÕL ò ò Installation Guide ...

Страница 2: ...E QuickTime UNIX Windows Windows Vista and WWW are registered trademarks of the respective holders Java and all Java based trademarks and logos are trademarks or registered trademarks of Oracle and or its affiliates UPnPTM is a certification mark of the UPnPTM Implementers Corporation SD SDHC and SDXC are trademarks or registered trademarks of SD 3C LLC in the United States other countries or both...

Страница 3: ...hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NO NO NOTICE TICE TICE Indicates a situation which if not avoided could result in damage to property Other Message Levels Important Indicates significant information which is essential for the product to function corr...

Страница 4: ...rd party Use only spare parts provided by or recommended by Axis Do not attempt to repair the product by yourself Contact Axis support or your Axis reseller for service matters Transportation NO NO NOTICE TICE TICE Keep the protective packaging When transporting the Axis product the protective packaging shall be replaced in its original position When transporting the Axis product use the original ...

Страница 5: ...ossible keep the protective plastic on the dome cover until the installation is complete Do not clean a dome cover that looks clean to the eye and never polish the surface Excessive cleaning could damage the surface For general cleaning of the dome cover it is recommended to use a non abrasive solvent free neutral soap or detergent mixed with pure water and a soft clean cloth Rinse well with pure ...

Страница 6: ... Dome Network Camera AXIS Q6044 S PTZ Dome Network Camera or AXIS Q6045 S Mk II PTZ Dome Network Camera AXIS T8605 Media Converter Switch Multi connector cable IP66 7 m 23 ft DIN rail clip Installation and Management Software CD Printed materials Installation Guide this document Extra serial number label 2x AVHS Authentication key Recommended Tools NO NO NOTICE TICE TICE Stainless steel is corrosi...

Страница 7: ... AXIS T94S01D Pole Bracket T91C67 Cable shoe pliers ground cable Media Converter Switch Diagonal pliers cables Wire stripping tool cable connecting Optional Accessories AXIS T91C61 Wall Mount AXIS T94S01D Pendant Kit AXIS T91C67 Pole Mount Sunshield Smoked dome cover AXIS T8008 PS12 Power Supply AXIS T8310 Video Surveillance Control Board AXIS T90B Illuminators Installation Display ...

Страница 8: ... 10 11 1 Mounting hole for sunshield 3x 2 Pressure relief valve 3 Multiconnector 4 Hook for safety wire 5 Guide hole 6 Inlet valve 7 Mounting hole 3x 8 Part number P N Serial number S N 9 SD card slot SDHC 10 Status LED indicator 11 Control button ENGLISH ...

Страница 9: ...AXIS Q60 S Series Dome Cover 1 3 4 2 5 6 1 Dome bracket screw T25 4x 2 Dome cover 3 Rubber gasket 4 Rubber gasket 5 Dome ring 6 Dome ring screw T20 4x Sunshield Sold Separately 1 1 Screw holes ...

Страница 10: ...ctor internal 4 Network slot SFP external 2x 5 Network connector RJ45 external 2x 6 Camera LED indicator 7 Network LED indicator 4x 8 Power LED indicator 9 Ground clip 10 I O connector internal 11 I O connector external 12 Multi connector cable 13 Ground screw LED Indicators Status LED Indication Unlit Connection and normal operation ENGLISH ...

Страница 11: ...tivity Connectors and Buttons For specifications and operating conditions see page 18 Network Connector NO NO NOTICE TICE TICE The product shall be connected using a shielded network cable STP All cables connecting the product to the network shall be intended for their specific use Make sure that the network devices are installed in accordance with the manufacturer s instructions For information a...

Страница 12: ...ting System service or AXIS Internet Dynamic DNS Service For more information about these services see the User Manual Multi Connector Cable Note The supplied multi connector cable is required in order to maintain the camera s NEMA IP rating The multi connector cable is connected to the camera s multi connector see Hardware Overview on page 11 The wires are connected to the supplied media converte...

Страница 13: ... 2x 11 Outer foil shield 12 Braided shield coil Function Pin wire Notes Specifications Digital input Connect to pin 8 to activate or leave floating unconnected to deactivate 0 to max 30 V DC Configurable Input or Output 2 blue 7 yellow Digital output Connected to pin 1 when activated floating unconnected when deactivated If used with an inductive load e g a relay a diode must be connected in paral...

Страница 14: ... on page 2 Important The media converter switch does not support hotswapping Disconnect power from the switch before swapping cameras An attempt to hotswap could cause the switch to freeze in which case it must be restarted Power connector DC input 2 pin terminal block for power input Power connector DC output Two 2 pin terminal block for power output pin 4 is not used Network connector RJ45 exter...

Страница 15: ...tivated by the VAPIX Application Programming Interface output buttons on the Live View page or by an Action Rule The output will show as active shown under System Options Port Devices Port Status if the alarm device is activated Digital input An alarm input for connecting devices that can toggle between an open and closed circuit for example PIRs door window contacts glass break detectors etc When...

Страница 16: ...tage SELV and Limited Power Source LPS use the power supply sold separately recommended by Axis Product Function Description AXIS Q6042 S AXIS Q6044 S AXIS Q6045 S Mk II Input power 12 V DC max 60 W Input voltage 12 0 13 2 V DC Input power 70 W min Available output power 65 W min Media converter switch Nominal output voltage 12 5 V DC 1 2 3 70 W 65 W 60 W 1 Media converter switch 2 Multi connector...

Страница 17: ...ground Make sure that both ends of the grounding wire are in contact with their respective grounding surfaces Power connector 2 pin terminal block for power input 2 1 Function Pin Notes Specifications 0 V DC 1 0 V DC DC input 12 V DC 2 Power in from power supply sold separately 12 0 13 2 V DC min 75 W I O terminal connector 6 pin terminal blocks for Digital Input Output Power DC output 0 V DC 2 1 ...

Страница 18: ...r Output 5 Digital output transistor open collector 0 to max 30 V DC open drain 100 mA Camera Connectors Power connector Two 2 pin terminal blocks for power output pin 4 is not used 2 1 4 3 Function Pin Notes Specifications 12 V DC 1 2 Power out to camera 12 0 13 2 V DC min 70 W 0 V DC 3 0 V DC DC output N a 4 N a Network connector Two 2 pin Ethernet terminal blocks I O terminal connector 2 pin te...

Страница 19: ... all the instructions before installing the product Some installation steps would benefit from being completed together because they require removal of the dome cover A hardware installation can include the following The product is supplied with a clear dome cover premounted A smoked dome cover is available as an accessory To replace the dome cover see page 22 A standard or high capacity SD card n...

Страница 20: ...using may drop below that pressure For full protection make sure that the pressure is above 0 2 bar 3 psi 1 Set the regulator gauge on the gas cylinder to 0 5 bar 7 psi 2 Remove the caps from the inlet valve and the pressure relief valve 3 Place the chuck on the inlet valve and press down to fill the camera with nitrogen 4 When the pressure inside the camera housing reaches 0 5 bar 7 psi the press...

Страница 21: ...etwork and that are routed outdoors or in demanding electrical environments shall be intended for their specific use Make sure that the network devices are installed in accordance with the manufacturer s instructions For information about regulatory requirements see Regulatory Information on page 2 Important Axis can only guarantee full functionality with the supplied media converter switch No oth...

Страница 22: ...coil 7 Cut off about 7 8 mm 0 27 0 32 in of the Ethernet wire foil shields 8 Strip off about 4 5 mm 0 16 0 20 in of the power wire jackets 1 2 2 3 4 1 Multi connector cable jacket 2 Outer foil shield 3 Braided shield 4 Ethernet wire foil shield 2x 9 Connect the network and I O wires to the internal network and I O connectors Open the lid insert the wires and close 10 Connect the ground and power w...

Страница 23: ...net wire green 5 Ethernet wire orange white 6 Ethernet wire orange 7 Digital I O wire yellow 8 Ground wire black 9 Power wire red 10 Power connector DC output 11 Ethernet connector internal 12 Ethernet connector internal 13 I O connector internal 14 Ground clip 15 Braided shield coil 16 Outer foil shield 17 Ethernet wire shield 2x 18 Clamp ...

Страница 24: ...ector cable jacket is firmly secured by the clamp Make sure all surfaces and contacts are clean and free from scrap shield material 12 Connect the network cables to the external network connectors RJ45 SFP as required Note An SFP module not included has to be used when connecting an optical fiber cable 1 2 8 3 4 5 6 7 1 Power cable DC input 2 Power connector DC input 3 Network connector SFP extern...

Страница 25: ...port that connects to another media converter switch to position C Leave the dip switch in its default position position B when connecting the port directly to the network For more information see Media Converter Switch Connectors on page 17 and the User Manual Important If the system is not defined use the default dip switch setting position B 1 1 Dip switch 4x 17 Attach the cover to the media co...

Страница 26: ...ain the IP66 protection the supplied multi connector cable shall be used 1 Install the selected bracket sold separately according to the instructions supplied with the bracket If drilling is required make sure to use drill bits screws and plugs that are appropriate for the material 2 Route the multi connector cable through the holes in the mounting bracket 3 Secure the camera using the supplied sa...

Страница 27: ...Connect the multi connector cable to the connector on the camera Use the alignment indicators to find the correct position NO NO NOTICE TICE TICE Be careful not do damage the multi connector cable when connecting it 6 Align the guide hole in the camera with the guide pin in the flange and fasten the network camera to the mounting bracket with the screws ...

Страница 28: ... connector cable 2 Alignment indicator camera 3 Flange 4 Multi connector cable 5 Guide hole Reset to Factory Default Settings Important Reset to factory default should be used with caution A reset to factory default will reset all settings including the IP address to the factory default values ENGLISH ...

Страница 29: ...e process is complete when the status LED indicator turns green The product has been reset to the factory default settings If no DHCP server is available on the network the default IP address is 192 168 0 90 5 Using the installation and management software tools assign an IP address set the password and access the video stream It is also possible to reset parameters to factory default via the web ...

Отзывы: