REGULATED DC POWER SUPPLY  

 

AX-3005DBL-one channel 

AX-3005DBL-3-three channel 

 

Instruction Manual 

Содержание AX-3005DBL

Страница 1: ...REGULATED DC POWER SUPPLY AX 3005DBL one channel AX 3005DBL 3 three channel Instruction Manual ...

Страница 2: ...lace as condensation might impair its operation 3 Do not expose the instrument to wet or dust environments 4 Do not place liquid filled containers such as coffee cups on top of this instrument A spill could seriously damage the instrument 5 Do not use this instrument where it is subject to serve vibration or strong blows 6 Do not place heavy objects on the case or otherwise block the ventilation h...

Страница 3: ...0V 10 50 60Hz OUTPUT VOLTAGE 0 30V 2x0 30V 5V CURRENT STEPWISE 50mA 5mA 50mA 3mA OUTPUT CURRENT 0 5A 2x0 5A 3A LINE REGULATION CV 0 02 2mV CC 0 05 5mA LOAD REGULATION CV 0 02 2mV CC 0 05 5mA RIPPLE NOISE CV 0 5mV CC 2mA OPERATING TEMPERATURE 0 40 C RELATIVE HUMIDITY 90 ...

Страница 4: ...e Figure 1 1 Output Voltage LCD Display 2 Output Current LCD Display 3 On Off Power Switch 4 Output terminals 5 Extended Output Terminals 6 Constant Voltage Display 7 Constant Current Display 8 Current Limit Adjustment Indicator ...

Страница 5: ...cator 3 Use a wire to shorten the and terminal at the output terminal 4 Push the UP or DOWN button to obtain the desired current value 5 When pushing and hold the UP or DOWN button over 0 8 sec the value will go up or go down continuously 6 Release the shortend wire connect the load to begin operation 7 The setting of current value will be stored in the EEPROM after power off 8 The current value w...

Страница 6: ...Voltage Display Ch 1 3 Constant Current Display Ch 1 4 Output Current Display Ch 1 5 Current Limit Adjustment Indicator Ch 1 6 Current Limit Up Setting Ch 1 7 Current Limit Down Setting Ch 1 8 C V C C Selection Switch Ch 1 9 Output Voltage Setting Ch 1 ...

Страница 7: ... Voltage LCD Display Ch 2 18 Constant Current Display Ch 2 19 Output Current Display Ch 2 20 Current Limit Adjustment Indicator Ch 2 21 C V C C Selection Switch Ch 2 22 Current Limit Down Setting Ch 2 23 Current Limit UP Setting Ch 2 24 Output Voltage Setting Ch 2 25 Output Terminals Ch 2 26 Extended Output Terminals Ch 2 27 Output Terminals for 5V 3A Ch 3 28 Power Switch 4 1 Constant voltage sett...

Страница 8: ...end wire connect the load to begin operation 7 The setting of current value will be stored in the EEPROM after off 8 The current value will be resumed by pushing the CV CC button when next power on 5 Serial function operating method 1 Turn on the power by pressing the POWER switch 2 Push the SERIAL button down to light up the indicator the dual power supply is now working under serial condition th...

Страница 9: ... value 3 Push the PARALLEL button down to light the indicator the unit is now working under parallel condition the maximum current possibly obtained is 6A 3003II 10A 3005XII 4 To obtain desired voltage by fine tuning any of the voltage setting knob 5 Push the PARALLEL button down again the light will be off this dual power supply will operate independently Figure 4 7 Dual function ...

Страница 10: ... you can perform the setting of CV CC procedures to get the desired current output 5 Do not forget to remove short wire of output terminals when operating in other mode Figure 5 8 Notices 1 When the operation is under PARALLEL condition when activating the SERIAL button the operation will be changed from PARALLEL condition to SERIAL condition 2 When the operation is under SERIAL condition when act...

Страница 11: ...4 When the unit is used with the high frequency instruments like ultrasonic soldering tool the electric power supply should be grounded Figure 6 ...