UMDIO128CO V2.0.1 Preliminary Documentation – May be Subject to Change A-1
APPENDIX A – Technical Specifications
Power Supply
Power Supply Input
12 or 24VDC nominal (8…32VDC power supply range)
Quiescent Current
75 mA at 12V Typical, 40 mA at 24V Typical
Maximum Current
400 mA +/- 50mA at 12V with all relay outputs energized
Protection
Reverse polarity protection is provided.
Power supply input section protects against transient surges and shorts.
Overvoltage protection up to 100V is provided. Able to withstand long time engine cranking.
Undervoltage protection down to ~7.5V is provided.
Inputs
Digital Inputs
12 digital active-low inputs with pull-up resistors.
ON voltage level: 0-0.8 V
OFF voltage level: 3.75V to +BAT
Input resistance: more than 5 k
Ω
(10k
Ω
pullup to +5Vdc)
The inputs have internal over and under voltage protection.
References
Four DGND references for inputs are provided
Outputs
Relay Outputs
8 Form C relay outputs.
Resistive load:
2 A (NO)/2 A (NC) at 125 VAC
2 A (NO)/2 A (NC) at 30 VDC
Dielectric strength:
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
There is no special overcurrent/overvoltage protection on the relay outputs. The user is
advised to provide a fast acting 3A fuse or an adequate external protection if necessary.
Indicator
Front panel Red-Green LED indicator. (See Table 1)
Communication
CAN
1 CAN 2.0B port, protocol CiA CANopen ®
Default baud rate 125 kbps, default Node-ID 127
By default, the DIO128 Controller transmits DI Read State 8-bit (6000h) and DO Read State
8-bit (2200h) on TPDO1
Network Termination
According to the CAN standard, it is necessary to terminate the network with external
termination resistors. The resistors are 120 Ohm, 0.25W minimum, metal film or similar
type. They should be placed between CAN_H and CAN_L terminals at both ends of the
network.
General Specifications
Control Logic
User programmable functionality using SDO object access, per CiA DS-301
User Interface
.EDS provided to interface to standard CANopen ® tools
Operating Conditions
-40 to 85
C (-40 to 185
F)
Protected against 95% humidity non-condensing, 30 to 60
C (86 to 140
F)
Storage
-50 to 120
C (-58 to 248
F)
Enclosure
Rugged aluminum housing, stainless steel end plates, neoprene gaskets
Conformal coated PCB assemblies and partially encapsulated
145.30 x 149.00 x 73.00 mm (5.72 x 5.86 x 2.87”) L x W x H
Connectors, Deutsch IPD P/N: 1 8-pin DT13-08PA, 1 40-pin DRC13-40PB
See Figure 6.
Protection IP67
Pollution Degree 3 rating per UL508
Weight 2.35
lb.(1.07 kg)
UL and cUL Compliance
UL508 (April 2010) (FTPM2) – Controls for Stationary Engine Driven Assemblies cUL C22.2
No. 14-10 (2010)
CE Compliance
2004/108/EC (EMC Directive)
2011/65/EU (RoHS Directive)
Vibration
4.3 G for off-engine mounting
The marine type approval process tested to 4.0 G per IEC 60068-2-6, Test Fc.
Marine Type Approval
Lloyd’s Register, DNV, ABS, RINA, GL, BV, CCS, IRS, RS
The AXDIO128CO meets the environmental, EMC and vibration requirements of generator
set applications in marine installations.