UMDIO128CO V2.0.1 Preliminary Documentation – May be Subject to Change 37-53
3.3.
APPLICATION OBJECTS (DS-401)
Index
(hex)
Object Object
Type
Data Type
Access
PDO
Mapping
6000h DI Read Input 8-bit
ARRAY UNSIGNED8
RO
Yes
6002h DI Polarity 8-bit
ARRAY UNSIGNED8
RW
No
6003h DI Filter Input 8-bit
ARRAY UNSIGNED8
RW
No
6005h DI Global Interrupt Enable 8-bit
ARRAY UNSIGNED8
RW
No
6006h DI Interrupt Mask Any Change 8-bit
ARRAY UNSIGNED8
RW
No
6007h DI Interrupt Mask Low-to-High 8-bit
ARRAY UNSIGNED8
RW
No
6008h DI Interrupt Mask High-to-Low 8-bit
ARRAY UNSIGNED8
RW
No
6200h DO Write Output 8-bit
ARRAY UNSIGNED8
RW
Yes
6202h DO
Polarity
8-bit
ARRAY UNSIGNED8
RW
No
6206h DO Error Mode 8-bit
ARRAY UNSIGNED8
RW
No
6207h DO Error Value 8-bit
ARRAY UNSIGNED8
RW
No
3.3.1.
Object 6000h: DI Read Input 8-bit
This read-only object represents the digital input state from 8 input lines. Refer to Section 1.4 for
more information. See Table 2 for bit order within the bytes. This object is mapped to TPDO1 by
default.
Object Description
Index 6000h
Name
DI Read Input 8-bit
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index 0h
Description Largest
sub-index supported
Access RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index 1h
Description
DI1 to DI8 State
Access RO
PDO Mapping
Yes
Value Range
FFh (255) [1111
1111b]
Default Value
No
Sub-Index 2h
Description
DI9 to DI12 State
Access RO
PDO Mapping
Yes
Value Range
0Fh (15) [0000
1111b]
Default Value
No