UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
96 - 141
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Override FV
Access
RW
PDO Mapping
No
Value Range
Dependent on type and range (see Table
15)
Default Value
500 [mV]
2.4.12. Object 2302h: AO Output Range
This object specifies the range of analog output. Together with Object 6310h AO Output type Output Range
specifies allowable ranges for output scaling objects, as defined in Table 17.
Object Description
Index
6310h
Name
AO Output Range
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Output Range
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (voltage 0 to 5V)
2.4.13. Object 2310h: AO Error Detect Enable
This object enables error detection and reaction associated with the analog output function block. When
disabled, the input will not generate an EMCY code in object 1003h Pre-Defined Error Field should the control
detect an open/short circuit at the load.
Object Description
Index
2310h
Name
AO Error Detect Enable
Object Type
ARRAY
Data Type
BOOLEAN
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No