UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
100 - 141
This object defines the number of the source that will be used to control the analog (or digital) output as shown
in the logic flowchart in Figure 12. The available control numbers are dependent on the source selected, as
shown in Table 23. Once selected, the control represents the process value (X-Axis input) in Figure 11.
Objects 6302h, 7320h, 7322h should therefore be updated to match the scaling limits defined by the control
source/number, as listed in Table 17.
Object Description
Index
2341h
Name
AO Control Input Number
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Control Input Number
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (control not used)
2.4.20. Object 2350h: AO Enable Input Source
This object defines the type of input that will be used to enable/disable the analog (or digital) output as shown
in the logic flowchart in Figure 12. The available control sources on the 2IN-2OUT-SIG-CO controller are listed
in Table 22
. Not all sources would make sense to enable the AO, and it is the user’s responsibility to select a
source that makes sense for the application.
Object Description
Index
2350h
Name
AO Enable Input Source
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Enable Input Source
Access
RW